Literature DB >> 15798319

Dose verification of single shot gamma knife applications using VIPAR polymer gel and MRI.

P Karaiskos1, L Petrokokkinos, E Tatsis, A Angelopoulos, P Baras, M Kozicki, P Papagiannis, J M Rosiak, L Sakelliou, P Sandilos, L Vlachos.   

Abstract

This work describes an experimental procedure with potential to assess the overall accuracy associated with gamma knife clinical applications, from patient imaging and dosimetry planning to patient positioning and dose delivery using the automated positioning system of a Leksell Gamma Knife model C. The VIPAR polymer gel-MRI dosimetry method is employed due to its inherent three-dimensional feature and linear dose response over the range of gamma knife applications. Different polymer gel vials were irradiated with single shot gamma knife treatment plans using each of the four available collimator helmets to deliver a maximum dose of 30 Gy. Percentage relative dose results are presented not only in the form of one-dimensional profiles but also planar isocontours and isosurfaces in three dimensions. Experimental results are compared with corresponding Gammaplan treatment planning system calculations as well as acceptance test radiochromic film measurements. A good agreement, within the experimental uncertainty, is observed between measured and expected dose distributions. This experimental uncertainty is of the order of one imaging pixel in the MRI gel readout session (<1 mm) and allows for the verification of single shot gamma knife applications in terms of acceptance specifications for precision in beam alignment and accuracy. Averaging net R(2) results in the dose plateau of the 4 mm and 18 mm collimator irradiated gel vials, which were MR scanned in the same session, provides a crude estimate of the 4 mm output factor which agrees within errors with the default value of 0.870.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15798319     DOI: 10.1088/0031-9155/50/6/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Commissioning and benchmarking a 3D dosimetry system for clinical use.

Authors:  Andrew Thomas; Joseph Newton; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

Review 2.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

3.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

4.  MRI-based polymer gel dosimetry for validating plans with multiple matrices in Gamma Knife stereotactic radiosurgery.

Authors:  N Gopishankar; Yoichi Watanabe; Vivekanandhan Subbiah
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

5.  Application of high field magnetic resonance microimaging in polymer gel dosimetry.

Authors:  Agnieszka Skorupa; Aleksandra Woźnica; Mateusz Ciszek; Michał Staniszewski; Marek Kijonka; Marek Kozicki; Bożena Woźniak; Andrzej Orlef; Andrzej Polański; Łukasz Boguszewicz; Maria Sokół
Journal:  Med Phys       Date:  2020-05-15       Impact factor: 4.071

6.  Mechanical and dose delivery accuracy evaluation in radiosurgery using polymer gels.

Authors:  Panagiotis Sandilos; Elias Tatsis; Lampros Vlachos; Pantelis Karaiskos; Evangelos Georgiou; Panagiotis Kipouros; Michael Torrens; Angelos Angelopoulos
Journal:  J Appl Clin Med Phys       Date:  2006-11-28       Impact factor: 2.102