The effect of overshooting the target strain on estimating viscoelastic properties from stress relaxation experiments.

Jonathan A Gimbel1, Joseph J Sarver, Louis J Soslowsky.   

Abstract

BACKGROUND: Tendon's mechanical behaviors have frequently been quantified using the quasi-linear viscoelastic (QLV) model. The QLV parameters are typically estimated by fitting the model to a single-step stress relaxation experiment. Unfortunately, overshoot of the target strain occurs to some degree in most experiments. This has never been formally investigated even though failing to measure, minimize, or compensate for overshoot may cause large errors in the estimation of parameters. Therefore, the objective of this study was to investigate the effect of overshoot on the estimation of QLV parameters. METHOD OF APPROACH: A simulated experiment was first performed to quantify the effect of different amounts of overshoot on the estimated QLV parameters. Experimental data from tendon was then used to determine if the errors associated with overshoot could be reduced when a direct fit is used (i.e., the actual strain history was used in the curve fit).
RESULTS: We found that both the elastic and viscous QLV parameters were incorrectly estimated if overshoot was not properly accounted for in the fit. Furthermore, the errors associated with overshoot were partially reduced when overshoot was accounted for using a direct fit.
CONCLUSIONS: A slow ramp rate is recommended to limit the amount of overshoot and a direct fit is recommended to limit the errors associated with overshoot, although other approaches such as adjusting the control system to limit overshoot could also be utilized.

Mesh:

Year:  2004        PMID: 15796344     DOI: 10.1115/1.1824132

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  8 in total

1.  A discrete spectral analysis for determining quasi-linear viscoelastic properties of biological materials.

Authors:  Behzad Babaei; Steven D Abramowitch; Elliot L Elson; Stavros Thomopoulos; Guy M Genin
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

2.  Collagen V-heterozygous and -null supraspinatus tendons exhibit altered dynamic mechanical behaviour at multiple hierarchical scales.

Authors:  Brianne K Connizzo; Lin Han; David E Birk; Louis J Soslowsky
Journal:  Interface Focus       Date:  2016-02-06       Impact factor: 3.906

3.  The effect of target strain error on plantar tissue stress.

Authors:  Shruti Pai; William R Ledoux
Journal:  J Biomech Eng       Date:  2010-07       Impact factor: 2.097

4.  Bioengineered stromal cell-derived factor-1α analogue delivered as an angiogenic therapy significantly restores viscoelastic material properties of infarcted cardiac muscle.

Authors:  Alen Trubelja; John W MacArthur; Joseph J Sarver; Jeffrey E Cohen; George Hung; Yasuhiro Shudo; Alexander S Fairman; Jay Patel; Bryan B Edwards; Scott M Damrauer; William Hiesinger; Pavan Atluri; Y Joseph Woo
Journal:  J Biomech Eng       Date:  2014-08       Impact factor: 2.097

5.  The quasi-linear viscoelastic properties of diabetic and non-diabetic plantar soft tissue.

Authors:  Shruti Pai; William R Ledoux
Journal:  Ann Biomed Eng       Date:  2011-02-15       Impact factor: 3.934

6.  Microscale Creep and Stress Relaxation Experiments with Individual Collagen Fibrils.

Authors:  Fan Yang; Debashish Das; Ioannis Chasiotis
Journal:  Opt Lasers Eng       Date:  2021-11-21       Impact factor: 4.836

7.  Alterations in function after rotator cuff tears in an animal model.

Authors:  Stephanie M Perry; Charles L Getz; Louis J Soslowsky
Journal:  J Shoulder Elbow Surg       Date:  2009 Mar-Apr       Impact factor: 3.019

8.  After rotator cuff tears, the remaining (intact) tendons are mechanically altered.

Authors:  Stephanie M Perry; Charles L Getz; Louis J Soslowsky
Journal:  J Shoulder Elbow Surg       Date:  2009 Jan-Feb       Impact factor: 3.019

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.