A dynamic renal phantom for nuclear medicine studies.

A S M SabbirAhmed1, Mustafa Demir, Levent Kabasakal, Ilhami Uslu.   

Abstract

Dynamic radionuclide renal study (renography) provides functional and structural information of the kidney and urinary tract noninvasively. Our purpose in this study is to describe the construction and test results of a dynamic renal phantom with different clinical features of radionuclide renography. The phantom consisted of five pieces of different shaped Plexiglas boxes: Two kidneys, one liver, two square shaped boxes (one heart and one bladder). The bladder was internally divided into two compartments in order to collect each kidney output separately. The dynamic circulation of the phantom was maintained under a hydrostatic pressure approximately equal to 13.3 kPa (average human blood pressure). The standard dose distribution among different organs and different renographic parameters were calculated from series of normal patients study (91 with 99mTc-DTPA, 68 with 99mTc-EC). All the studies were performed with same camera (Siemens Orbiter Digitrac 7500) equipped with LEAP (low energy all purpose) collimator using ADAC Pegasys II analytic package program under the same clinical procedure. Different regions of interest (ROIs) were drawn for concerning organs and counts per second (CPS) were collected for each ROI. The series of renogram curves were generated by phantom-studies with different flow rates for left kidney (LK) and right kidney (RK). The renal index (RI) for an individual study was calculated as the product of two indexes: "Relative Renal Function" (RRF) (water-volume of LK/RK) and "Relative Renal Time" (RRT) (Tmax of LK/RK). The most significant correlation was found in total CPS for LK and RK between the EC group and phantom studies (p < 0.001). The calculated RI values were used to simulate the patients' study with different clinical features. The dynamics were found reproducible. The phantom is suitable for using in calibration and quality control protocols of the renogram procedure used in Nuclear Medicine.

Entities:  

Mesh:

Year:  2005        PMID: 15789599     DOI: 10.1118/1.1851923

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Development and prospective evaluation of an automated software system for quality control of quantitative 99mTc-MAG3 renal studies.

Authors:  Russell D Folks; Ernest V Garcia; Andrew T Taylor
Journal:  J Nucl Med Technol       Date:  2007-03

2.  Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and its Performance.

Authors:  Takashi Kamiya; Tadashi Watabe; Koichi Fujino; Romanov Victor; Yoshiki Kawamura; Kayako Isohashi; Keiko Matsunaga; Mitsuaki Tatsumi; Hiroki Kato; Eku Shimosegawa; Jun Hatazawa
Journal:  Asia Ocean J Nucl Med Biol       Date:  2019
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.