Application of lot sampling of sputum AFB smears for the assessment of microscopy centres.

N Selvakumar1, E Prabhakaran, B N Murthy, S Sivagamasundari, S Vasanthan, R Govindaraju, M Perumal, F Wares, L S Chauhan, T Santha, P R Narayanan.   

Abstract

SETTING: Designated microscopy centres (DMC) and additional microscopy centres (AMC) performing sputum acid-fast bacilli (AFB) microscopy, the District TB Centre (DTC) and a reference laboratory (RL).
OBJECTIVES: To ascertain the feasibility of adopting lot sampling of AFB smears and to assess the performance of MCs employing Senior Tuberculosis Laboratory Supervisors (STLS) with no knowledge about the principles of quality assurance of AFB microscopy and RL-based laboratory technicians with training on quality assurance for blinded checking of AFB smears.
METHODS: Slides from MCs were transported to the DTC and the RL; 20 smears per month per MC were selected systematically; 1547 slides from DMCs and 726 from AMCs were checked, respectively, by STLSs at the DTC and by RL laboratory technicians. Discrepancies were resolved by referee.
RESULTS: The discrepancy between MC laboratory technicians and STLSs at the DTC was 4.7%, compared to 1% at the RL. The STLSs and RL-based laboratory technicians had 70 and 2 errors, respectively.
CONCLUSIONS: Lot sampling of AFB smears is feasible under field conditions. Assessment of MCs was more valid with RL-based technicians trained in principles of quality assurance of sputum AFB microscopy than with STLSs with no such training and working in the field.

Entities:  

Mesh:

Year:  2005        PMID: 15786895

Source DB:  PubMed          Journal:  Int J Tuberc Lung Dis        ISSN: 1027-3719            Impact factor:   2.373


  3 in total

1.  Lot quality assurance sampling of sputum acid-fast bacillus smears for assessing sputum smear microscopy centers.

Authors:  N Selvakumar; B N Murthy; E Prabhakaran; S Sivagamasundari; Samuel Vasanthan; M Perumal; R Govindaraju; L S Chauhan; Fraser Wares; T Santha; P R Narayanan
Journal:  J Clin Microbiol       Date:  2005-02       Impact factor: 5.948

2.  Sputum smear microscopy: evaluation of impact of training, microscope distribution, and use of external quality assessment guidelines for resource-poor settings.

Authors:  A Van Rie; D Fitzgerald; G Kabuya; A Van Deun; M Tabala; N Jarret; F Behets; E Bahati
Journal:  J Clin Microbiol       Date:  2008-01-03       Impact factor: 5.948

3.  External quality assessment in resource-limited countries.

Authors:  Jane Y Carter
Journal:  Biochem Med (Zagreb)       Date:  2017-02-15       Impact factor: 2.313

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.