Lot quality assurance sampling of sputum acid-fast bacillus smears for assessing sputum smear microscopy centers.

N Selvakumar1, B N Murthy, E Prabhakaran, S Sivagamasundari, Samuel Vasanthan, M Perumal, R Govindaraju, L S Chauhan, Fraser Wares, T Santha, P R Narayanan.   

Abstract

Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast bacillus microscopy centers in national tuberculosis control programs.

Entities:  

Mesh:

Year:  2005        PMID: 15695704      PMCID: PMC548059          DOI: 10.1128/JCM.43.2.913-915.2005

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Lot quality assurance sampling (LQAS) for monitoring a leprosy elimination program.

Authors:  M D Gupte; B Narasimhamurthy
Journal:  Int J Lepr Other Mycobact Dis       Date:  1999-06

2.  Application of lot sampling of sputum AFB smears for the assessment of microscopy centres.

Authors:  N Selvakumar; E Prabhakaran; B N Murthy; S Sivagamasundari; S Vasanthan; R Govindaraju; M Perumal; F Wares; L S Chauhan; T Santha; P R Narayanan
Journal:  Int J Tuberc Lung Dis       Date:  2005-03       Impact factor: 2.373

3.  Lot quality assurance sampling techniques in health surveys in developing countries: advantages and current constraints.

Authors:  C F Lanata; R E Black
Journal:  World Health Stat Q       Date:  1991

4.  The status and prospects of tuberculosis control in India.

Authors:  G R Khatri; T R Frieden
Journal:  Int J Tuberc Lung Dis       Date:  2000-03       Impact factor: 2.373

5.  Blinded rechecking of sputum smears for acid-fast bacilli to ensure the quality and usefulness of restaining smears to assess false-positive errors.

Authors:  N Selvakumar; E Prabhakaran; F Rahman; N A Chandu; S Srinivasan; T Santha; L S Chauhan; P R Narayanan
Journal:  Int J Tuberc Lung Dis       Date:  2003-11       Impact factor: 2.373

  5 in total
  4 in total

1.  Sputum smear microscopy: evaluation of impact of training, microscope distribution, and use of external quality assessment guidelines for resource-poor settings.

Authors:  A Van Rie; D Fitzgerald; G Kabuya; A Van Deun; M Tabala; N Jarret; F Behets; E Bahati
Journal:  J Clin Microbiol       Date:  2008-01-03       Impact factor: 5.948

2.  Tuberculosis Laboratory Diagnosis Quality Assurance among Public Health Facilities in West Amhara Region, Ethiopia.

Authors:  Melashu Balew Shiferaw; Hiwot Amare Hailu; Abebe Alemu Fola; Mulatu Melese Derebe; Aimro Tadese Kebede; Abayneh Admas Kebede; Manamnot Agegne Emiru; Zelalem Dessie Gelaw
Journal:  PLoS One       Date:  2015-09-16       Impact factor: 3.240

3.  External quality assessment in resource-limited countries.

Authors:  Jane Y Carter
Journal:  Biochem Med (Zagreb)       Date:  2017-02-15       Impact factor: 2.313

4.  Factors which contributed for low quality sputum smears for the detection of acid fast bacilli (AFB) at selected health centers in Ethiopia: A quality control perspective.

Authors:  Ayehu Mekonen; Yeshi Ayele; Yifru Berhan; Desalegn Woldeyohannes; Woldaregay Erku; Solomon Sisay
Journal:  PLoS One       Date:  2018-06-20       Impact factor: 3.240

  4 in total