Literature DB >> 15786448

Functionalization of dental implant surfaces using adhesion molecules.

H Schliephake1, D Scharnweber, M Dard, A Sewing, A Aref, S Roessler.   

Abstract

The aim of the present study was to test the hypothesis that organic coating of titanium screw implants that provides binding sites for integrin receptors can enhance periimplant bone formation. Ten adult female foxhounds received experimental titanium screw implants in the mandible 3 months after removal of all premolar teeth. Four types of implants were evaluated in each animal: (1) implants with machined titanium surface, (2) implants coated with collagen I, (3) implants with collagen I and cyclic RGD peptide coating (Arg-Gly-Asp) with low RGD concentrations (100 micromol/mL), and (4) implants with collagen I and RGD coating with high RGD concentrations (1000 micromol/mL). Periimplant bone regeneration was assessed histomorphometrically after 1 and 3 months in five dogs each by measuring bone implant contact (BIC) and the volume density of the newly formed periimplant bone (BVD). After 1 month, BIC was significantly enhanced only in the group of implants coated with the higher concentration of RGD peptides (p = 0.026). Volume density of the newly formed periimplant bone was significantly higher in all implants with organic coating. No significant difference was found between collagen coating and RGD coatings. After 3 months, BIC was significantly higher in all implants with organic coating than in implants with machined surfaces. Periimplant BVD was significantly increased in all coated implants in comparison to machined surfaces also. It was concluded that organic coating of machined screw implant surfaces providing binding sites for integrin receptors can enhance bone implant contact and periimplant bone formation. (c) 2004 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15786448     DOI: 10.1002/jbm.b.30183

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  22 in total

1.  Interactions between endothelial progenitor cells (EPC) and titanium implant surfaces.

Authors:  Thomas Ziebart; Anne Schnell; Christian Walter; Peer W Kämmerer; Andreas Pabst; Karl M Lehmann; Johanna Ziebart; Marc O Klein; Bilal Al-Nawas
Journal:  Clin Oral Investig       Date:  2012-03-10       Impact factor: 3.573

Review 2.  Organic-inorganic surface modifications for titanium implant surfaces.

Authors:  Lise T de Jonge; Sander C G Leeuwenburgh; Joop G C Wolke; John A Jansen
Journal:  Pharm Res       Date:  2008-05-29       Impact factor: 4.200

Review 3.  Implants in bone: part I. A current overview about tissue response, surface modifications and future perspectives.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-24

4.  Ultrathin sP(EO-stat-PO) hydrogel coatings are biocompatible and preserve functionality of surface bound growth factors in vivo.

Authors:  Carl Neuerburg; Stefan Recknagel; Jörg Fiedler; Jürgen Groll; Martin Moeller; Kristina Bruellhoff; Heiko Reichel; Anita Ignatius; Rolf E Brenner
Journal:  J Mater Sci Mater Med       Date:  2013-06-26       Impact factor: 3.896

Review 5.  Biomimetic coatings for bone tissue engineering of critical-sized defects.

Authors:  Yuelian Liu; Gang Wu; Klaas de Groot
Journal:  J R Soc Interface       Date:  2010-05-19       Impact factor: 4.118

Review 6.  Nanotechnology approaches to improve dental implants.

Authors:  Antoni P Tomisa; Maximilien E Launey; Janice S Lee; Mahesh H Mankani; Ulrike G K Wegst; Eduardo Saiz
Journal:  Int J Oral Maxillofac Implants       Date:  2011       Impact factor: 2.804

7.  Stem cell-mediated functionalization of titanium implants.

Authors:  Deanna Ingrassia; Martina Sladkova; Michael Palmer; Wei Xia; Håkan Engqvist; Giuseppe Maria de Peppo
Journal:  J Mater Sci Mater Med       Date:  2017-07-25       Impact factor: 3.896

Review 8.  Silicon micro- and nanofabrication for medicine.

Authors:  Daniel Fine; Alessandro Grattoni; Randy Goodall; Shyam S Bansal; Ciro Chiappini; Sharath Hosali; Anne L van de Ven; Srimeenkashi Srinivasan; Xuewu Liu; Biana Godin; Louis Brousseau; Iman K Yazdi; Joseph Fernandez-Moure; Ennio Tasciotti; Hung-Jen Wu; Ye Hu; Steve Klemm; Mauro Ferrari
Journal:  Adv Healthc Mater       Date:  2013-04-15       Impact factor: 9.933

9.  Implementation of new software for fast screening of cell compatibility on surface modifications using low-contrast time-lapsed microscopy.

Authors:  Dan Dominik Brüllmann; Marc O Klein; Bilal Al-Nawas; Sigrid Horn; Verena Büsser; Barbara Jung; Wilfried Wagner; Bernd d'Hoedt
Journal:  Clin Oral Investig       Date:  2009-08-21       Impact factor: 3.573

10.  Characterization of collagen II fibrils containing biglycan and their effect as a coating on osteoblast adhesion and proliferation.

Authors:  Timothy Douglas; Sascha Heinemann; Ute Hempel; Carolin Mietrach; Christiane Knieb; Susanne Bierbaum; Dieter Scharnweber; Hartmut Worch
Journal:  J Mater Sci Mater Med       Date:  2007-09-13       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.