Literature DB >> 15774593

In vivo absorbed dose measurements in mammography using a new real-time luminescence technique.

M C Aznar1, B Hemdal, J Medin, C J Marckmann, C E Andersen, L Bøtter-Jensen, I Andersson, S Mattsson.   

Abstract

A dosimetry system based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon doped aluminium oxide (Al2O3:C) crystals was developed for in vivo absorbed dose measurements in mammography. A small cylindrical crystal of Al2O3:C (diameter 0.48 mm and length 2 mm) was coupled to the end of a 1 mm diameter optical fibre cable. Owing to their small size and characteristic shape, these probes can be placed on the body surface in the field of view during the examination, without compromising the reading of the mammogram. Our new technique was tested with a mammography unit (Siemens Mammomat 3000) and screen-film technique over a range of clinically relevant X-ray energies. The results were compared with those obtained from an ionization chamber usually used for the determination of absorbed dose in mammography. The reproducibility of measurements was around 3% (1 standard deviation) at 4.5 mGy for both RL and OSL data. The dose response was found to be linear between 4.5 mGy and 30 mGy. The energy dependence of the system is around 18% between 23 kV and 35 kV. In vivo measurements were performed during three patient examinations. It was shown that entrance and exit doses could be measured. The presence of the small probes did not significantly interfere with the diagnostic quality of the images. Entrance doses estimated by RL/OSL results agreed within 3% with entrance surface dose values calculated from the ionization chamber measurements. These results indicate a considerable potential for use in routine control and in vivo dose measurements in mammography.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15774593     DOI: 10.1259/bjr/22554286

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Characterization of the nanoDot OSLD dosimeter in CT.

Authors:  Sarah B Scarboro; Dianna Cody; Paola Alvarez; David Followill; Laurence Court; Francesco C Stingo; Di Zhang; Michael McNitt-Gray; Stephen F Kry
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Dosimetry in x-ray-based breast imaging.

Authors:  David R Dance; Ioannis Sechopoulos
Journal:  Phys Med Biol       Date:  2016-09-12       Impact factor: 3.609

3.  Energy dependence and angular dependence of an optically stimulated luminescence dosimeter in the mammography energy range.

Authors:  Ai Kawaguchi; Yuta Matsunaga; Shoichi Suzuki; Koichi Chida
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

4.  Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications.

Authors:  A S Pradhan; J I Lee; J L Kim
Journal:  J Med Phys       Date:  2008-07

5.  Characterization of scintillating X-ray optical fiber sensors.

Authors:  Dan Sporea; Laura Mihai; Ion Vâţă; Denis McCarthy; Sinead O'Keeffe; Elfed Lewis
Journal:  Sensors (Basel)       Date:  2014-02-19       Impact factor: 3.576