Literature DB >> 15773729

Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams.

E Pedroni1, S Scheib, T Böhringer, A Coray, M Grossmann, S Lin, A Lomax.   

Abstract

In this paper we present the pencil beam dose model used for treatment planning at the PSI proton gantry, the only system presently applying proton therapy with a beam scanning technique. The scope of the paper is to give a general overview on the various components of the dose model, on the related measurements and on the practical parametrization of the results. The physical model estimates from first physical principles absolute dose normalized to the number of incident protons. The proton beam flux is measured in practice by plane-parallel ionization chambers (ICs) normalized to protons via Faraday-cup measurements. It is therefore possible to predict and deliver absolute dose directly from this model without other means. The dose predicted in this way agrees very well with the results obtained with ICs calibrated in a cobalt beam. Emphasis is given in this paper to the characterization of nuclear interaction effects, which play a significant role in the model and are the major source of uncertainty in the direct estimation of the absolute dose. Nuclear interactions attenuate the primary proton flux, they modify the shape of the depth-dose curve and produce a faint beam halo of secondary dose around the primary proton pencil beam in water. A very simple beam halo model has been developed and used at PSI to eliminate the systematic dependences of the dose observed as a function of the size of the target volume. We show typical results for the relative (using a CCD system) and absolute (using calibrated ICs) dosimetry, routinely applied for the verification of patient plans. With the dose model including the nuclear beam halo we can predict quite precisely the dose directly from treatment planning without renormalization measurements, independently of the dose, shape and size of the dose fields. This applies also to the complex non-homogeneous dose distributions required for the delivery of range-intensity-modulated proton therapy, a novel therapy technique developed at PSI.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15773729     DOI: 10.1088/0031-9155/50/3/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  51 in total

1.  Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.

Authors:  L Archambault; F Poenisch; N Sahoo; D Robertson; A Lee; M T Gillin; R Mohan; S Beddar
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  18F-FET-PET-based dose painting by numbers with protons.

Authors:  Mark Rickhey; Zdenek Morávek; Christoph Eilles; Oliver Koelbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2010-05-21       Impact factor: 3.621

3.  An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle.

Authors:  Gabriel O Sawakuchi; Dragan Mirkovic; Luis A Perles; Narayan Sahoo; X Ron Zhu; George Ciangaru; Kazumichi Suzuki; Michael T Gillin; Radhe Mohan; Uwe Titt
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

4.  Adjustment of the lateral and longitudinal size of scanned proton beam spots using a pre-absorber to optimize penumbrae and delivery efficiency.

Authors:  Uwe Titt; Dragan Mirkovic; Gabriel O Sawakuchi; Luis A Perles; Wayne D Newhauser; Phillip J Taddei; Radhe Mohan
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

5.  Theoretical detection threshold of the proton-acoustic range verification technique.

Authors:  Moiz Ahmad; Liangzhong Xiang; Siavash Yousefi; Lei Xing
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

6.  Assessment of out-of-field absorbed dose and equivalent dose in proton fields.

Authors:  Ben Clasie; Andrew Wroe; Hanne Kooy; Nicolas Depauw; Jay Flanz; Harald Paganetti; Anatoly Rosenfeld
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

7.  Radiotherapy in ophthalmology : 2004 Jules Gonin lecture of the Retina Research Foundation.

Authors:  Leonidas Zografos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-07       Impact factor: 3.117

8.  A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries.

Authors:  David C Westerly; Xiaohu Mo; Wolfgang A Tomé; Thomas R Mackie; Paul M DeLuca
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

9.  Technical Note: Optimization of spot and trimmer position during dynamically collimated proton therapy.

Authors:  Blake R Smith; Daniel E Hyer; Ryan T Flynn; Wesley S Culberson
Journal:  Med Phys       Date:  2019-03-05       Impact factor: 4.071

10.  Impact of range shifter material on proton pencil beam spot characteristics.

Authors:  Jiajian Shen; Wei Liu; Aman Anand; Joshua B Stoker; Xiaoning Ding; Mirek Fatyga; Michael G Herman; Martin Bues
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.