How much margin reduction is possible through gating or breath hold?

M Engelsman1, G C Sharp, T Bortfeld, R Onimaru, H Shirato.   

Abstract

We determined the relationship between intra-fractional breathing motion and safety margins, using daily real-time tumour tracking data of 40 patients (43 tumour locations), treated with radiosurgery at Hokkaido University. We limited our study to the dose-blurring effect of intra-fractional breathing motion, and did not consider differences in positioning accuracy or systematic errors. The additional shift in the prescribed isodose level (e.g. 95 %) was determined by convolving a one-dimensional dose profile, having a dose gradient representing an 8 MV beam through either lung or water, with the probability density function (PDF) of breathing. This additional shift is a measure for the additional margin that should be applied in order to maintain the same probability of tumour control as without intra-fractional breathing. We show that the required safety margin is a nonlinear function of the peak-to-peak breathing motion. Only a small reduction in the shift of isodose curves was observed for breathing motion up to 10 mm. For larger motion, 20 or 30 mm, control of patient breathing during irradiation, using either gating or breath hold, can allow a substantial reduction in safety margins of about 7 or 12 mm depending on the dose gradient prior to blurring. Clinically relevant random setup uncertainties, which also have a blurring effect on the dose distribution, have only a small effect on the margin needed for intra-fractional breathing motion. Because of the one-dimensional nature of our analysis, the resulting margins are mainly applicable in the superior-inferior direction. Most measured breathing PDFs were not consistent with the PDF of a simple parametric curve such as cos4, either because of irregular breathing or base-line shifts. Instead, our analysis shows that breathing motion can be modelled as Gaussian with a standard deviation of about 0.4 times the peak-to-peak breathing motion.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15773724     DOI: 10.1088/0031-9155/50/3/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

Review 1.  A review of image-guided radiotherapy.

Authors:  George T Y Chen; Gregory C Sharp; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2008-12-16

2.  Optimizing principal component models for representing interfraction variation in lung cancer radiotherapy.

Authors:  Ahmed M Badawi; Elisabeth Weiss; William C Sleeman; Chenyu Yan; Geoffrey D Hugo
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

3.  Tumor trailing strategy for intensity-modulated radiation therapy of moving targets.

Authors:  Alexei Trofimov; Christian Vrancic; Timothy C Y Chan; Gregory C Sharp; Thomas Bortfeld
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  On-line target position localization in the presence of respiration: a comparison of two methods.

Authors:  Geoffrey D Hugo; Jian Liang; Jonathan Campbell; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-29       Impact factor: 7.038

5.  Cumulative lung dose for several motion management strategies as a function of pretreatment patient parameters.

Authors:  Geoffrey D Hugo; Jonathon Campbell; Tiezhi Zhang; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-26       Impact factor: 7.038

6.  A 4D IMRT planning method using deformable image registration to improve normal tissue sparing with contemporary delivery techniques.

Authors:  Xiaoqiang Li; Xiaochun Wang; Yupeng Li; Xiaodong Zhang
Journal:  Radiat Oncol       Date:  2011-07-19       Impact factor: 3.481

7.  Margin selection to compensate for loss of target dose coverage due to target motion during external-beam radiation therapy of the lung.

Authors:  W Kyle Foster; Ernest Osei; Rob Barnett
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

8.  Four-dimensional CT-based evaluation of volumetric modulated arc therapy for abdominal lymph node metastasis from hepatocellular carcinoma.

Authors:  Li Zhang; Mian Xi; Xiao-Wu Deng; Qiao-Qiao Li; Xiao-Yan Huang; Meng-Zhong Liu
Journal:  J Radiat Res       Date:  2012-06-28       Impact factor: 2.724

9.  Influence of increased target dose inhomogeneity on margins for breathing motion compensation in conformal stereotactic body radiotherapy.

Authors:  Anne Richter; Kurt Baier; Juergen Meyer; Juergen Wilbert; Thomas Krieger; Michael Flentje; Matthias Guckenberger
Journal:  BMC Med Phys       Date:  2008-12-03

10.  Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer.

Authors:  Ylanga G van der Geld; Frank J Lagerwaard; John R van Sörnsen de Koste; Johan P Cuijpers; Ben J Slotman; Suresh Senan
Journal:  Radiat Oncol       Date:  2006-11-01       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.