Literature DB >> 15769704

Coronary artery bypass with the use of a magnetic distal anastomotic device: surgical technique and preliminary experience.

Thanos Athanasiou1, Hutan Ashrafian, Brian Glenville, Roberto Casula.   

Abstract

BACKGROUND: At present there is little reported experience in the application of new technology in the performance of distal coronary anastomoses in the clinical setting. The aim of our study was to evaluate the feasibility of using the Ventrica magnetic vascular positioner (MVP) device for left internal thoracic artery (LITA)-to-left anterior descending (LAD) coronary anastomosis.
METHODS: We present our preliminary experience of the first 14 coronary artery cases performed in the United Kingdom from April 2003 to December 2003. The selection criteria, surgical technique, clinical outcome, advantages or disadvantages, and future implications are all discussed.
RESULTS: The device was used in 12 patients for LITA-to-LAD anastomosis and in 2 patients for the proximal anastomosis of a radial artery Y-graft from the LITA to the circumflex territories. The first 3 patients underwent coronary artery bypass graft with the use of cardiopulmonary bypass, and the remaining 9 underwent surgery performed using an off-pump coronary artery bypass technique. No mortality or device-related events were observed in these patients. The anastomosis time in our series was 5.6 +/- 1.99 minutes, and the blood loss was 914 +/- 234 mL. The mean length of stay was 5.8 +/- 1.16 days.
CONCLUSION: The MVP system is a novel distal coronary anastomotic device that is quick, simple, and effective, producing consistently reliable coronary anastomoses in a wide variety of coronary bypass procedures. Early results are encouraging, and further studies are required in order to evaluate long-term efficacy of this system in the rapidly changing world of coronary revascularization.

Entities:  

Mesh:

Year:  2004        PMID: 15769704     DOI: 10.1532/HSF98.2004-1024

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  2 in total

1.  Extrahepatic portacaval shunt via a magnetic compression technique: A cadaveric feasibility study.

Authors:  Xiao-Peng Yan; Wen-Yan Liu; Jia Ma; Jian-Peng Li; Yi Lv
Journal:  World J Gastroenterol       Date:  2015-07-14       Impact factor: 5.742

2.  Novel magnetic compression technique for establishment of a canine model of tracheoesophageal fistula.

Authors:  Yi Gao; Rong-Qian Wu; Yi Lv; Xiao-Peng Yan
Journal:  World J Gastroenterol       Date:  2019-08-14       Impact factor: 5.742

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.