Literature DB >> 15762263

Computer-assisted fluoroscopic navigation of pedicle screw insertion: an in vivo feasibility study.

Tsai-Sheng Fu1, Li-Huei Chen, Chak-Bor Wong, Po-Liang Lai, Tsung-Ting Tsai, Chi-Chieh Niu, Wen-Jer Chen.   

Abstract

BACKGROUND: Accurate placement of pedicle screws is difficult. PATIENTS AND METHODS: We evaluated the feasibility and accuracy of pedicle screw insertion assisted by a real-time, 2-dimensional (2D) image-guided navigation system in 12 patients who underwent thoraco-lumbar and/or lumbar stabilization. 66 pedicle screws were inserted either by senior spine surgeons or residents. The accuracy of positioning of the screws was evaluated using postoperative plain radiographs and thin-cut CT.
RESULTS: 61 of the 66 screws were inserted successfully. 5 screw insertions showed structural violations: 4 on the medial and 1 on the lateral pedicle wall. The accuracy was higher in the sagittal plane than in the axial plain. There was no difference between the surgical error rates caused by the senior surgeons and the residents.
INTERPRETATION: Using computer-assisted 2D fluoroscopic image navigation, it is possible to achieve reliable and accurate pedicle screw insertion during low thoracic and lumbar spinal surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15762263     DOI: 10.1080/00016470410004102

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  14 in total

1.  Is intraoperative CT of posterior cervical spine instrumentation cost-effective and does it reduce complications?

Authors:  Andrew C Hecht; Steven M Koehler; Janelle C Laudone; Arthur Jenkins; Sheeraz Qureshi
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

2.  Pedicle screw insertion: computed tomography versus fluoroscopic image guidance.

Authors:  Tsai-Sheng Fu; Chak-Bor Wong; Tsung-Ting Tsai; Yen-Chiu Liang; Lih-Huei Chen; Wen-Jer Chen
Journal:  Int Orthop       Date:  2007-04-05       Impact factor: 3.075

3.  Image-guided pedicle screw insertion accuracy: a meta-analysis.

Authors:  Nai-Feng Tian; Hua-Zi Xu
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

Review 4.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

5.  Use of computed tomographic reconstruction to establish the ideal entry point for pedicle screws in idiopathic scoliosis.

Authors:  Peiqiang Su; Wentong Zhang; Yan Peng; Anjing Liang; Kaili Du; Dongsheng Huang
Journal:  Eur Spine J       Date:  2011-08-13       Impact factor: 3.134

6.  Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?

Authors:  Michael David Kraus; Gert Krischak; Peter Keppler; Florian T Gebhard; Uwe H W Schuetz
Journal:  Clin Orthop Relat Res       Date:  2010-06-03       Impact factor: 4.176

Review 7.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

Authors:  Ioannis D Gelalis; Nikolaos K Paschos; Emilios E Pakos; Angelos N Politis; Christina M Arnaoutoglou; Athanasios C Karageorgos; Avraam Ploumis; Theodoros A Xenakis
Journal:  Eur Spine J       Date:  2011-09-07       Impact factor: 3.134

8.  Navigated pedicle screw placement using computed tomographic data in dorsolumbar fractures.

Authors:  Saurabh Kapoor; Rajbahadur Sharma; Sudhir Garg; Rohit Jindal; Ravi Gupta; Anshul Goe
Journal:  Indian J Orthop       Date:  2014-11       Impact factor: 1.251

9.  Navigation-assisted fluoroscopy in minimally invasive direct lateral interbody fusion: a cadaveric study.

Authors:  Jonathan E Webb; Gilad J Regev; Steven R Garfin; Choll W Kim
Journal:  SAS J       Date:  2010-12-01

10.  Accuracy of free hand pedicle screw installation in the thoracic and lumbar spine by a young surgeon: an analysis of the first consecutive 306 screws using computed tomography.

Authors:  Chang-Hyun Lee; Seung-Jae Hyun; Yongjung J Kim; Ki-Jeong Kim; Tae-Ahn Jahng; Hyun-Jib Kim
Journal:  Asian Spine J       Date:  2014-06-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.