Literature DB >> 15753795

Agreement between four available algorithms to evaluate global systolic left and right ventricular function from tomographic radionuclide ventriculography and comparison with planar imaging.

Pieter De Bondt1, Olivier De Winter, Johan De Sutter, Rudi Andre Dierckx.   

Abstract

BACKGROUND AND AIM: Left and right ventricular ejection fractions (LVEF and RVEF) and end-diastolic and end-systolic volumes (LVEDV, RVEDV, LVESV and RVESV) can be calculated from tomographic radionuclide ventriculography (TRV). The aim of this study was to validate and compare these parameters obtained using four different TRV software programs (QBS, QUBE, 4D-MSPECT and BP-SPECT).
METHODS: LVEF obtained from planar radionuclide ventriculography (PRV) was compared with LVEF obtained from TRV using the four different software programs in 166 patients. Furthermore, ventricular volumes obtained using TRV (QBS, QUBE and 4D-MSPECT) were compared with those obtained using BP-SPECT, the latter being the only method with the validation of ventricular volumes in the literature.
RESULTS: The correlation of LVEF between PRV and TRV was good for all methods: 0.81 for QBS, 0.79 for QUBE, 0.71 for 4D-MSPECT and 0.79 for BP-SPECT. The mean differences+/-standard deviation (SD) were 3.16+/-9.88, 10.72+/-10.92, 3.43+/-11.79 and 2.91+/-10.39, respectively. The correlation of RVEF between BP-SPECT and QUBE and QBS was poor: 0.33 and 0.38, respectively. LV volumes calculated using QBS, QUBE and 4D-MSPECT correlated well with those obtained using BP-SPECT (0.98, 0.90 and 0.98, respectively), with mean differences+/-SD of 7.31+/-42.94, -22.09+/-36.07 and -40.55+/-39.36, respectively. RV volumes showed poorer correlation between QBS and BP-SPECT and between QUBE and BP-SPECT (0.82 and 0.57, respectively).
CONCLUSION: LVEF calculated using TRV correlates well with that calculated using PRV, but is not interchangeable with the value obtained using PRV. Volume calculations (for left and right ventricle) and RVEF require further validation before they can be used in clinical practice.

Entities:  

Mesh:

Year:  2005        PMID: 15753795     DOI: 10.1097/00006231-200504000-00008

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  7 in total

1.  SPECT versus planar gated blood pool imaging for left ventricular evaluation.

Authors:  François Harel; Vincent Finnerty; Quam Ngo; Jean Grégoire; Paul Khairy; Bernard Thibault
Journal:  J Nucl Cardiol       Date:  2007-06-27       Impact factor: 5.952

Review 2.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

3.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

4.  Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting.

Authors:  Laurent Dercle; Monia Ouali; Pierre Pascal; Thomas Giraudmaillet; Roland Chisin; Olivier Lairez; Marie-Agnès Marachet; Hervé Rousseau; Delphine Bastié; Fayçal Ben Bouallègue; Isabelle Berry
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

5.  Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data.

Authors:  Hubert Tissot; Véronique Roch; Olivier Morel; Nicolas Veran; Mathieu Perrin; Marine Claudin; Antoine Verger; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-27       Impact factor: 5.952

6.  Proposed volume-based methods for correcting the shift in left ventricular ejection fraction from blood-pool gated SPECT.

Authors:  Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-19       Impact factor: 5.952

7.  Comparison of radionuclide ventriculography using SPECT and planar techniques in different cardiac conditions.

Authors:  Teresa Massardo; Rodrigo Jaimovich; Hugo Lavados; Daniela Gutiérrez; J Carlos Rodríguez; J Miguel Saavedra; Rita Alay; Héctor Gatica
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06-20       Impact factor: 10.057

  7 in total