Literature DB >> 1575335

Spinal cord stimulation evoked potentials during thoracoabdominal aortic aneurysm surgery.

B Drenger1, S D Parker, R W McPherson, R B North, G M Williams, B A Reitz, C Beattie.   

Abstract

Although monitoring of somatosensory evoked potentials elicited from stimulation of lower extremity peripheral nerves has been suggested as a method for assessing neural function during thoracoabdominal aortic aneurysm surgery, this technique has been reported to yield a large number of false positives. It was believed that direct stimulation of the spinal cord would eliminate some of the problems associated with peripheral evoked potentials. The present study compared in 18 patients the use of scalp recorded evoked potential following stimulation of either the posterior tibial nerve via percutaneous needles or the spinal cord via an epidural electrode previously placed fluoroscopically. In 10 patients in whom distal bypass or shunt was not used, peripheral evoked potentials totally disappeared within 5-30 min of aortic clamping. Spinal cord stimulation evoked potentials disappeared permanently in 2 patients shortly after aortic cross-clamping; 1 died shortly after the procedure, and the other awoke densely paraplegic and died the next day. When distal perfusion was maintained by shunt or bypass, the disappearance of both peripheral and spinal evoked potentials accurately predicted the neurologic outcome of 1 paralyzed patient. Loss of spinal cord stimulation evoked potentials was found to be correlated with adverse neurologic outcome. Over the period of aortic clamping a gradual decrease in mean amplitude (50% at 45 min [P less than 0.05]) and a 20% increase in mean latency time were observed. Maintenance of adequate distal perfusion may permit the use of peripheral evoked potentials in the assessment of spinal cord ischemia during aortic cross-clamping.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1575335     DOI: 10.1097/00000542-199205000-00005

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  2 in total

1.  Transtracheal electrical stimulation of the spinal cord for intraoperative monitoring of the motor pathway.

Authors:  G I Csécsei; L Mikó; G Székely; C Molnár; A Balogh; I Furka; I Mikó
Journal:  Neurosurg Rev       Date:  1998       Impact factor: 3.042

2.  Unintended perioperative hypothermia.

Authors:  Stuart R Hart; Brianne Bordes; Jennifer Hart; Daniel Corsino; Donald Harmon
Journal:  Ochsner J       Date:  2011
  2 in total