Laurence Lamboursain1, Mario Jolicoeur.
Abstract
Microscopic counting of plant cells is a very tedious and time-consuming process and is therefore seldom used to evaluate plant cell number on a routine basis. This study describes a fast and simple method to evaluate cell concentration in a plant cell suspension using a fluorescence microplate reader. Eschscholtzia californica cells were fixed in a mix of methanol and acetic acid (3:1) and stained with a fluorescent DNA binding dye (Hoechst 33258). Readings were done in a fluorescence microplate reader at 360/465 nm. Specific binding of the dye to double-stranded DNA was significantly favored over unspecific binding when 1.0 M Tris buffer at pH 7.5 containing 1.0 M NaCl and 75 microg ml(-1) of Hoechst 33258 was used. Fluorescence readings must be done between 4 min and 12 min following the addition of the staining solution to the sample. The microplate counting method provides a convenient, rapid and sensitive procedure for determining the cell concentration in plant cell suspensions. The assay has a linear detection range from 0.2 x 10(6) cells to 10.0 x 10(6) cells per milliliter (actual concentration in the tested cell suspension). The time needed to perform the microplate counting was 10% of that needed for the microscopic enumeration. However, this microplate counting method can only be used on genetically stable cell lines and on asynchronous cell suspensions.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15747158 DOI: 10.1007/s00299-004-0899-3
Source DB: PubMed Journal: Plant Cell Rep ISSN: 0721-7714 Impact factor: 4.570