Optimal mitral annular and subvalvular shape change created by the Coapsys device to treat functional mitral regurgitation.

Kiyotaka Fukamachi1, Masahiro Inoue, Zoran Popović, Yoshio Ootaki, Michael W Kopcak, Raymond Dessoffy, James D Thomas, Patrick M McCarthy.   

Abstract

We have reported that the Myocor Coapsys (Myocor, Inc, Maple Grove, MN) device treated functional mitral regurgitation (MR) by reducing mitral annular dimension and repositioning papillary muscles. This study was conducted to evaluate the optimal Coapsys device sizing level. The Coapsys device was implanted in seven dogs after induction of MR by rapid ventricular pacing. The device consists of anterior and posterior pads connected by a subvalvular cord. The device was tightened in 5% increments of the left ventricular epicardial to epicardial dimension up to 40%. Hemodynamic and echocardiographic measurements were repeated at each tightening level. The Coapsys significantly reduced or eliminated functional MR, and the reduction was maximized at the 30% tightening level or lower in all cases. Although the left ventricular end diastolic volume decreased significantly, forward stroke volume was maintained until the 35% tightening level. The forward ejection fraction significantly increased from 33 +/- 24% at baseline to 62 +/- 42% at 40% tightening level. Mean aortic pressure decreased slightly but significantly. The Coapsys device can be applied over a broad range of tightening levels with significant reduction in MR without negative physiologic impact. This feature makes the device usable [corrected] in a variety of clinical settings.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  2005        PMID: 15745128     DOI: 10.1097/01.mat.0000150511.87747.a1

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

Review 1.  Percutaneous valve repair and replacement techniques.

Authors:  B Munt; J Webb
Journal:  Heart       Date:  2005-12-09       Impact factor: 5.994

Review 2.  Left ventricular restoration devices.

Authors:  Guilherme H Oliveira; Sadeer G Al-Kindi; Hiram G Bezerra; Marco A Costa
Journal:  J Cardiovasc Transl Res       Date:  2014-02-27       Impact factor: 4.132

Review 3.  Diastolic ventricular support with cardiac support devices: an alternative approach to prevent adverse ventricular remodeling.

Authors:  Pavan Atluri; Michael A Acker
Journal:  Heart Fail Rev       Date:  2013-01       Impact factor: 4.214

Review 4.  Percutaneous and off-pump treatments for functional mitral regurgitation.

Authors:  Kiyotaka Fukamachi
Journal:  J Artif Organs       Date:  2008-04-15       Impact factor: 1.731

Review 5.  New Insights in the Diagnosis and Treatment of Heart Failure.

Authors:  Giulio Agnetti; Massimo F Piepoli; Giuseppe Siniscalchi; Francesco Nicolini
Journal:  Biomed Res Int       Date:  2015-10-26       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.