Cerebral tissue oxygenation in reversible focal ischemia in rats: multi-site EPR oximetry measurements.

Huagang Hou1, Oleg Y Grinberg, Stalina A Grinberg, Eugene Demidenko, Harold M Swartz.   

Abstract

Multi-site electron paramagnetic resonance (EPR) oximetry was used in vivo to measure the partial pressure of oxygen (pO2) in reversible focal ischemia in rats. The cerebral tissue pO2 was measured simultaneously and continuously at two sites on the ischemic side and one on the normal side of the brain in the same animal prior to and at several time points after ischemia and reperfusion. The O2 at the three different sites in brain was stable over 30 min of baseline measurements. During the first 120 min of ischemia, statistically significant decreases in brain pO2 from baseline were consistently observed in the ischemic core and perifocal area. The mean values varied during the 120 min of ischemia. Reperfusion resulted in an immediate increase in PO2, but there were no significant differences between the sites over time. The result of this study seems promising for the study of ischemia and reperfusion. It appears that the technique can provide information on the PO2 under the experimental conditions needed for such a study. The levels of PO2 that occurred in these experiments are readily resolvable by multi-site EPR oximetry. In addition, the ability simultaneously to measure the pO2 in several sites provides important additional information that should help to differentiate between changes in the PO2 due toglobal or local mechanisms.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15742885     DOI: 10.1088/0967-3334/26/1/012

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  9 in total

1.  Repeated assessment of orthotopic glioma pO(2) by multi-site EPR oximetry: a technique with the potential to guide therapeutic optimization by repeated measurements of oxygen.

Authors:  Nadeem Khan; Sriram Mupparaju; Huagang Hou; Benjamin B Williams; Harold Swartz
Journal:  J Neurosci Methods       Date:  2011-11-04       Impact factor: 2.390

Review 2.  Repetitive tissue pO2 measurements by electron paramagnetic resonance oximetry: current status and future potential for experimental and clinical studies.

Authors:  Nadeem Khan; Benjamin B Williams; Huagang Hou; Hongbin Li; Harold M Swartz
Journal:  Antioxid Redox Signal       Date:  2007-08       Impact factor: 8.401

3.  Cerebral oxygenation of the cortex and striatum following normobaric hyperoxia and mild hypoxia in rats by EPR oximetry using multi-probe implantable resonators.

Authors:  Huagang Hou; Hongbin Li; Ruhong Dong; Sriram Mupparaju; Nadeem Khan; Harold Swartz
Journal:  Adv Exp Med Biol       Date:  2011       Impact factor: 2.622

4.  Dynamic EPR Oximetry of Changes in Intracerebral Oxygen Tension During Induced Thromboembolism.

Authors:  Huagang Hou; Nadeem Khan; Sangeeta Gohain; Clifford J Eskey; Karen L Moodie; Kirk J Maurer; Harold M Swartz; Periannan Kuppusamy
Journal:  Cell Biochem Biophys       Date:  2017-04-22       Impact factor: 2.194

5.  Application of in vivo EPR for tissue pO2 and redox measurements.

Authors:  Nadeem Khan; Dipak K Das
Journal:  Methods Mol Biol       Date:  2009

6.  Tibial fracture decreases oxygen levels at the site of injury.

Authors:  Chuanyong Lu; Mark Rollins; Huagang Hou; Harold M Swartz; Harriet Hopf; Theodore Miclau; Ralph S Marcucio
Journal:  Iowa Orthop J       Date:  2008

7.  Tissue pO2 of orthotopic 9L and C6 gliomas and tumor-specific response to radiotherapy and hyperoxygenation.

Authors:  Nadeem Khan; Hongbin Li; Huagang Hou; Jean P Lariviere; David J Gladstone; Eugene Demidenko; Harold M Swartz
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-01-10       Impact factor: 7.038

8.  Real-time monitoring of ischemic and contralateral brain pO2 during stroke by variable length multisite resonators.

Authors:  Huagang Hou; Hongbin Li; Ruhong Dong; Nadeem Khan; Harold Swartz
Journal:  Magn Reson Imaging       Date:  2014-02-10       Impact factor: 2.546

9.  A Review of Low-Frequency EPR Technology for the Measurement of Brain pO2 and Oxidative Stress.

Authors:  John Weaver; Ke Jian Liu
Journal:  Appl Magn Reson       Date:  2021-07-16       Impact factor: 0.974

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.