Literature DB >> 15742716

Feasibility study of the use of similarity maps in the evaluation of oncological dynamic positron emission tomography images.

T Thireou1, G Kontaxakis, L G Strauss, A Dimitrakopoulou-Strauss, S Pavlopoulos, A Santos.   

Abstract

A preliminary study is presented on the potential role of similarity mapping (SM) in the evaluation of oncological dynamic 18F-fluorodeoxyglucose positron emission tomography studies, mainly in lesion localisation and detectability. Similarity maps were calculated using previously described (correlation coefficient (COR) and normalised correlation coefficient (NCOR)) and newly introduced similarity measures (sum of squares coefficient (SSQ), squared sum coefficient (SQS), sum of cubes coefficient (SC) and cubed sum coefficient (CS)). The results were evaluated using simulated and clinical data. The study revealed that the best-suited similarity measure for such applications was the CS similarity coefficient, which provided the best parametric images, delineating structures of interest and supporting the visual interpretation of data sets. It was shown that SM and standardised uptake value (SUV) images had comparable diagnostic performance, although SM was able to offer additional time-related information in a single image. For the case of colorectal recurrences (17 cases), the measured contrast values for the CS and SUV images were 2.36 +/- 0.47 and 4.12 +/- 0.42, respectively, whereas, for three cases of giant cell tumours, these values were 11.6 +/- 2.1 and 11.9 +/- 1.8, respectively.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15742716     DOI: 10.1007/bf02345119

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  25 in total

1.  Guest editorial: the conception of FDG-PET imaging.

Authors:  Abass Alavi; Martin Reivich
Journal:  Semin Nucl Med       Date:  2002-01       Impact factor: 4.446

Review 2.  A tabulated summary of the FDG PET literature.

Authors:  S S Gambhir; J Czernin; J Schwimmer; D H Silverman; R E Coleman; M E Phelps
Journal:  J Nucl Med       Date:  2001-05       Impact factor: 10.057

3.  Temporal covariance analysis of first-pass contrast-enhanced myocardial magnetic resonance images.

Authors:  A O Boudraa; F Behloul; M Janier; E Canet; J Champier; J P Roux; D Revel
Journal:  Comput Biol Med       Date:  2001-03       Impact factor: 4.589

4.  Anatomy of SUV. Standardized uptake value.

Authors:  S C Huang
Journal:  Nucl Med Biol       Date:  2000-10       Impact factor: 2.408

5.  Shortened PET data acquisition protocol for the quantification of 18F-FDG kinetics.

Authors:  Ludwig G Strauss; Antonia Dimitrakopoulou-Strauss; Uwe Haberkorn
Journal:  J Nucl Med       Date:  2003-12       Impact factor: 10.057

6.  Applications of similarity mapping in dynamic MRI.

Authors:  J Rogowska; K Preston; G J Hunter; L M Hamberg; K K Kwong; O Salonen; G L Wolf
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

7.  Segmentation strategies for breast tumors from dynamic MR images.

Authors:  F A Lucas-Quesada; U Sinha; S Sinha
Journal:  J Magn Reson Imaging       Date:  1996 Sep-Oct       Impact factor: 4.813

8.  A comparative analysis of similarity mapping and eigenimaging as applied to dynamic MR imaging of a low grade astrocytoma.

Authors:  J Rogowska; K Preston; H J Aronen; G L Wolf
Journal:  Acta Radiol       Date:  1994-07       Impact factor: 1.990

9.  Analysis of dynamic nuclear cardiac images by covariance function.

Authors:  A O Boudraa; J Champier; M Djebali; F Behloul; A Beghdadi
Journal:  Comput Med Imaging Graph       Date:  1999 Jul-Aug       Impact factor: 4.790

Review 10.  The applications of PET in clinical oncology.

Authors:  L G Strauss; P S Conti
Journal:  J Nucl Med       Date:  1991-04       Impact factor: 10.057

View more
  2 in total

Review 1.  Kinetic modeling and parametric imaging with dynamic PET for oncological applications: general considerations, current clinical applications, and future perspectives.

Authors:  Antonia Dimitrakopoulou-Strauss; Leyun Pan; Christos Sachpekidis
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-05-19       Impact factor: 9.236

2.  Automatic mapping extraction from multiecho T2-star weighted magnetic resonance images for improving morphological evaluations in human brain.

Authors:  Shaode Yu; Shibin Wu; Yaoqin Xie
Journal:  Comput Math Methods Med       Date:  2013-11-27       Impact factor: 2.238

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.