Literature DB >> 15734427

Facilitated minimally invasive left ventricular epicardial lead placement.

Nicolas Doll1, Ulrich T Opfermann, Ardawan J Rastan, Thomas Walther, Hendrik Bernau, Jan F Gummert, Friedrich W Mohr.   

Abstract

PURPOSE: Atrial-synchronized biventricular pacing is an effective treatment option in patients with heart failure and interventricular conduction delay. Owing to a failed transvenous implantation in some patients, the left ventricular (LV) lead has to be placed surgically, usually by an anterolateral thoracotomy. We used a novel malleable epicardial lead placement tool (Epicardial Lead Implant Tool, Model 10626; Medtronic, Minneapolis, MN) that facilitates lead placement on the posterior aspect of the LV through an anterolateral minithoracotomy. DESCRIPTION: The tool consists of a malleable steel shaft with distal gripping tongs for the epicardial lead. Proximally, a thumbwheel and an actuator button allow fixation and release of the lead on the myocardium. EVALUATION: We used this tool in 7 patients through an anterolateral minithoracotomy. All patients had a safe, successful, and rather short procedure. No scopes were required.
CONCLUSIONS: Epicardial LV lead placement through an anterolateral minithoracotomy is facilitated by using the Lead Implant Tool. Lead placement is achieved by the malleable shaft design, which enables perpendicular implantation of the lead pad on the posterior LV surface with an anterolateral approach.

Entities:  

Mesh:

Year:  2005        PMID: 15734427     DOI: 10.1016/j.athoracsur.2004.01.026

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

Review 1.  Lead positioning strategies to enhance response to cardiac resynchronization therapy.

Authors:  Dan Blendea; Jagmeet P Singh
Journal:  Heart Fail Rev       Date:  2011-05       Impact factor: 4.214

2.  Left ventricular endocardial pacing in cardiac resynchronisation therapy: Moving from bench to bedside.

Authors:  F A Bracke; B M van Gelder; L R C Dekker; P Houthuizen; J F Ter Woorst; J A Teijink
Journal:  Neth Heart J       Date:  2012-03       Impact factor: 2.380

3.  Endovascular bi-ventricular pacing-defibrillator placement using a trans-atrial approach.

Authors:  Michael C Giudici; Nicholas V Augelli; Charles A Longo; Cynthia J Meierbachtol
Journal:  J Interv Card Electrophysiol       Date:  2009-06-20       Impact factor: 1.900

  3 in total