Literature DB >> 15734323

Trap for MAbs: characterization of intact monoclonal antibodies using reversed-phase HPLC on-line with ion-trap mass spectrometry.

John C Le1, Pavel V Bondarenko.   

Abstract

For the first time, the characterization of intact 150-kDa monoclonal antibodies (MAbs) using a commercially available three-dimensional ion-trap mass spectrometer (IT-MS) is reported. The IT-MS analysis was performed on-line with reversed-phase high performance liquid chromatography (RP-HPLC) on a POROS column using a nontraditional solvent system of acetonitrile, isopropanol, ethanol, and water in formic acid. The operating parameters of the IT-MS were optimized by extending the mass range to m/z 4000 and elevating the tube lens offset voltage value to around -100 V. Mass accuracy better than 300 ppm (+/-40 Da) has been routinely achieved for these macromolecules. Multiple peaks 162 Da apart due to the hexose variants of the monoclonal IgG antibodies were partially resolved in mass spectra. Several commercial and chimeric antibodies have been investigated in this study.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15734323     DOI: 10.1016/j.jasms.2004.11.004

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  20 in total

Review 1.  Contributions of mass spectrometry to structural immunology.

Authors:  K M Downard
Journal:  J Mass Spectrom       Date:  2000-04       Impact factor: 1.982

Review 2.  Antibody humanization: a case of the 'Emperor's new clothes'?

Authors:  M Clark
Journal:  Immunol Today       Date:  2000-08

3.  Affinity-reversed-phase liquid chromatography assay to quantitate recombinant antibodies and antibody fragments in fermentation broth.

Authors:  J E Battersby; B Snedecor; C Chen; K M Champion; L Riddle; M Vanderlaan
Journal:  J Chromatogr A       Date:  2001-08-24       Impact factor: 4.759

4.  Identification of multiple sources of charge heterogeneity in a recombinant antibody.

Authors:  R J Harris; B Kabakoff; F D Macchi; F J Shen; M Kwong; J D Andya; S J Shire; N Bjork; K Totpal; A B Chen
Journal:  J Chromatogr B Biomed Sci Appl       Date:  2001-03-10

5.  Development of an analytical reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry method for characterization of recombinant antibodies.

Authors:  Thomas M Dillon; Pavel V Bondarenko; Margaret Speed Ricci
Journal:  J Chromatogr A       Date:  2004-10-22       Impact factor: 4.759

6.  Monitoring of IgG antibody thermal stability by micellar electrokinetic capillary chromatography and matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  A J Alexander; D E Hughes
Journal:  Anal Chem       Date:  1995-10-15       Impact factor: 6.986

7.  Rapid characterization of chemically-modified proteins by electrospray mass spectrometry.

Authors:  K L Bennett; S V Smith; R M Lambrecht; R J Truscott; M M Sheil
Journal:  Bioconjug Chem       Date:  1996 Jan-Feb       Impact factor: 4.774

8.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

9.  Reflecting time-of-flight mass spectrometer with an electrospray ion source and orthogonal extraction.

Authors:  A N Verentchikov; W Ens; K G Standing
Journal:  Anal Chem       Date:  1994-01-01       Impact factor: 6.986

10.  Enhanced sensitivity for peptide mapping with electrospray liquid chromatography-mass spectrometry in the presence of signal suppression due to trifluoroacetic acid-containing mobile phases.

Authors:  A Apffel; S Fischer; G Goldberg; P C Goodley; F E Kuhlmann
Journal:  J Chromatogr A       Date:  1995-09-29       Impact factor: 4.759

View more
  4 in total

1.  Mass measurement and top-down HPLC/MS analysis of intact monoclonal antibodies on a hybrid linear quadrupole ion trap-Orbitrap mass spectrometer.

Authors:  Pavel V Bondarenko; Tonya P Second; Vlad Zabrouskov; Alexander A Makarov; Zhongqi Zhang
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-28       Impact factor: 3.109

2.  Electrospray ionization quadrupole ion-mobility time-of-flight mass spectrometry as a tool to distinguish the lot-to-lot heterogeneity in N-glycosylation profile of the therapeutic monoclonal antibody trastuzumab.

Authors:  Carola W N Damen; Weibin Chen; Asish B Chakraborty; Mike van Oosterhout; Jeffrey R Mazzeo; John C Gebler; Jan H M Schellens; Hilde Rosing; Jos H Beijnen
Journal:  J Am Soc Mass Spectrom       Date:  2009-08-07       Impact factor: 3.109

3.  Application of triple quadrupole mass spectrometry for the characterization of antibody-drug conjugates.

Authors:  Malin Källsten; Matthijs Pijnappel; Rafael Hartmann; Fredrik Lehmann; Lucia Kovac; Sara Bergström Lind; Jonas Bergquist
Journal:  Anal Bioanal Chem       Date:  2019-03-08       Impact factor: 4.142

4.  Characterization of therapeutic proteins by cation exchange chromatography-mass spectrometry and top-down analysis.

Authors:  Rachel Liuqing Shi; Gang Xiao; Thomas M Dillon; Margaret S Ricci; Pavel V Bondarenko
Journal:  MAbs       Date:  2020 Jan-Dec       Impact factor: 5.857

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.