Literature DB >> 15733766

Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques.

Tom P Aufderheide1, Ronald G Pirrallo, Demetris Yannopoulos, John P Klein, Chris von Briesen, Christopher W Sparks, Kimberly A Deja, Craig J Conrad, David J Kitscha, Terry A Provo, Keith G Lurie.   

Abstract

BACKGROUND: Complete chest wall recoil improves hemodynamics during cardiopulmonary resuscitation (CPR) by generating relatively negative intrathoracic pressure and thus draws venous blood back to the heart, providing cardiac preload prior to the next chest compression phase.
OBJECTIVE: Phase I was an observational case series to evaluate the quality of chest wall recoil during CPR performed by emergency medical services (EMS) personnel on patients with an out-of-hospital cardiac arrest. Phase II was designed to assess the quality of CPR delivered by EMS personnel using an electronic test manikin. The goal was to determine if a change in CPR technique or hand position would improve complete chest wall recoil, while maintaining adequate duty cycle, compression depth, and correct hand position placement. Standard manual CPR and three alternative manual CPR approaches were assessed. METHODS AND
RESULTS: Phase I--The clinical observational study was performed by an independent observer noting incomplete chest wall decompression and correlating that observation with electronically measured airway pressures during CPR in adult patients with out-of-hospital cardiac arrest. Rescuers were observed to maintain some residual and continuous pressure on the chest wall during the decompression phase of CPR, preventing full chest wall recoil, at some time during resuscitative efforts in 6 (46%) of 13 consecutive adults (average +/- S.D. age 63 +/-5.8 years). Airway pressures were consistently positive during the decompression phase (>0 mmHg) during those observations. Phase II: This randomized prospective trial was performed on an electronic test manikin. Thirty EMS providers (14 EMT-Basics, 5 EMT-Intermediates, and 11 EMT-Paramedics), with an average age +/- S.D. of 32 +/- 8 years and 6.5 +/- 4.2 years of EMS experience, performed 3 min of CPR on a Laerdal Skill Reporter CPR manikin using the Standard Hand Position followed by 3 min of CPR (in random order) using three alternative CPR techniques: (1) Two-Finger Fulcrum Technique--lifting the heel of the hand slightly but completely off the chest during the decompression phase of CPR using the thumb and little finger as a fulcrum; (2) Five-Finger Fulcrum Technique--lifting the heel of the hand slightly but completely off the chest during the decompression phase of CPR using all five fingers as a fulcrum; and (3) Hands-Off Technique--lifting the heel and all fingers of the hand slightly but completely off the chest during the decompression phase of CPR. These EMS personnel did not know the purpose of the studies prior to or during this investigation. Adequate compression depth was poor for all hand positions tested and ranged only from 29.9 to 48.5% of all compressions. When compared with the Standard Hand Position, the Hands-Off Technique decreased mean compression duty cycle from 46.9 +/- 6.4% to 33.3 +/- 4.6%, (P < 0.0001) but achieved the highest rate of complete chest wall recoil (95.0% versus 16.3%, P < 0.0001) and was 129 times more likely to provide complete chest wall recoil (OR: 129.0; CI: 43.4-382.0). There were no significant differences in accuracy of hand placement, depth of compression, or reported increase in fatigue or discomfort with its use compared with the Standard Hand Position.
CONCLUSIONS: Incomplete chest wall decompression was observed at some time during resuscitative efforts in 6 (46%) of 13 consecutive adult out-of-hospital cardiac arrests. The Hands-Off Technique decreased compression duty cycle but was 129 times more likely to provide complete chest wall recoil (OR: 129.0; CI: 43.4-382.0) compared to the Standard Hand Position without differences in accuracy of hand placement, depth of compression, or reported increase in fatigue or discomfort with its use. All forms of manual CPR tested (including the Standard Hand Position) in professional EMS rescuers using a recording manikin produced an inadequate depth of compression more than half the time. These data support development and testing of more effective means to deliver manual as well as mechanical CPR.

Entities:  

Mesh:

Year:  2005        PMID: 15733766     DOI: 10.1016/j.resuscitation.2004.10.007

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  24 in total

1.  From laboratory science to six emergency medical services systems: New understanding of the physiology of cardiopulmonary resuscitation increases survival rates after cardiac arrest.

Authors:  Tom P Aufderheide; Carly Alexander; Charles Lick; Brent Myers; Laurie Romig; Levon Vartanian; Joseph Stothert; Scott McKnite; Tim Matsuura; Demetris Yannopoulos; Keith Lurie
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

2.  Pediatric cardiopulmonary resuscitation and stabilization.

Authors:  Atul Jindal; M Jayashree; Sunit C Singhi
Journal:  Indian J Pediatr       Date:  2011-05-25       Impact factor: 1.967

3.  The prevalence of chest compression leaning during in-hospital cardiopulmonary resuscitation.

Authors:  David A Fried; Marion Leary; Douglas A Smith; Robert M Sutton; Dana Niles; Daniel L Herzberg; Lance B Becker; Benjamin S Abella
Journal:  Resuscitation       Date:  2011-04-08       Impact factor: 5.262

4.  Prevalence and hemodynamic effects of leaning during CPR.

Authors:  Dana E Niles; Robert M Sutton; Vinay M Nadkarni; Andrew Glatz; Mathias Zuercher; Matthew R Maltese; Joar Eilevstjønn; Benjamin S Abella; Lance B Becker; Robert A Berg
Journal:  Resuscitation       Date:  2011-12       Impact factor: 5.262

5.  Standard cardiopulmonary resuscitation versus active compression-decompression cardiopulmonary resuscitation with augmentation of negative intrathoracic pressure for out-of-hospital cardiac arrest: a randomised trial.

Authors:  Tom P Aufderheide; Ralph J Frascone; Marvin A Wayne; Brian D Mahoney; Robert A Swor; Robert M Domeier; Michael L Olinger; Richard G Holcomb; David E Tupper; Demetris Yannopoulos; Keith G Lurie
Journal:  Lancet       Date:  2011-01-22       Impact factor: 79.321

6.  Effect of residual leaning force on intrathoracic pressure during mechanical ventilation in children.

Authors:  Robert Michael Sutton; Dana Niles; Jon Nysaether; Mette Stavland; Melissa Thomas; Susan Ferry; Ram Bishnoi; Ronald Litman; Julian Allen; Vijay Srinivasan; Robert A Berg; Vinay M Nadkarni
Journal:  Resuscitation       Date:  2010-04-20       Impact factor: 5.262

7.  Part 12: Education, implementation, and teams: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations.

Authors:  Jasmeet Soar; Mary E Mancini; Farhan Bhanji; John E Billi; Jennifer Dennett; Judith Finn; Matthew Huei-Ming Ma; Gavin D Perkins; David L Rodgers; Mary Fran Hazinski; Ian Jacobs; Peter T Morley
Journal:  Resuscitation       Date:  2010-10       Impact factor: 5.262

8.  Leaning during chest compressions impairs cardiac output and left ventricular myocardial blood flow in piglet cardiac arrest.

Authors:  Mathias Zuercher; Ronald W Hilwig; James Ranger-Moore; Jon Nysaether; Vinay M Nadkarni; Marc D Berg; Karl B Kern; Robert Sutton; Robert A Berg
Journal:  Crit Care Med       Date:  2010-04       Impact factor: 7.598

9.  Resuscitation Outcomes Consortium (ROC) PRIMED cardiac arrest trial methods part 1: rationale and methodology for the impedance threshold device (ITD) protocol.

Authors:  Tom P Aufderheide; Peter J Kudenchuk; Jerris R Hedges; Graham Nichol; Richard E Kerber; Paul Dorian; Daniel P Davis; Ahamed H Idris; Clifton W Callaway; Scott Emerson; Ian G Stiell; Thomas E Terndrup
Journal:  Resuscitation       Date:  2008-05-19       Impact factor: 5.262

10.  Improved chest recoil using an adhesive glove device for active compression-decompression CPR in a pediatric manikin model.

Authors:  Jai P Udassi; Sharda Udassi; Melissa A Lamb; Kenneth E Lamb; Douglas W Theriaque; Jonathan J Shuster; Arno L Zaritsky; Ikram U Haque
Journal:  Resuscitation       Date:  2009-08-15       Impact factor: 5.262