Literature DB >> 15733507

Role of different nocturnal monitorings in the evaluation of CPAP titration by autoCPAP devices.

Oreste Marrone1, Giuseppe Insalaco, Adriana Salvaggio, Giovanni Bonsignore.   

Abstract

The aim of the study was to assess how the analysis of different signals recorded during application of automatic continuous positive airway pressure (autoCPAP) devices improves the evaluation of pressure titration in patients with obstructive sleep apnea syndrome (OSAS) naive to treatment. Seventy-two patients underwent nocturnal polysomnography during autoCPAP (Autoset T, ResMed, Sydney, Australia) application. Progressively more complex combinations of signals were analysed in consecutive steps. According to the analysis of oxyhemoglobin saturation (SaO(2)) alone, a fixed CPAP level suitable for treatment could not be identified in 3 subjects. When analysis of posture was added, titration was considered unsatisfactory in 1 more subject, due to a short time spent supine. Further, addition of flow and respiratory movements led to consider titration unsatisfactory in 1 more subject. Analysis of all polysomnographic signals demonstrated a not fully reliable titration in 9 subjects: 1 with short sleep duration, 2 without REM sleep, 4 with a short sleep time spent supine, and 3 subjects (already identified by SaO(2)) with insufficient correction of respiratory disorders even when a relatively high CPAP was administered. Mask leaks did not hamper titration. CPAP titration by automatic devices alone results in imperfect titration in >10% subjects naive to ventilatory treatment. Only polysomnographic recording ensures titration reliability in all patients. Further research is needed to identify simple and economic methods to reliably start the CPAP treatment.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15733507     DOI: 10.1016/j.rmed.2004.07.018

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  3 in total

1.  The need for pressure changes in CPAP therapy 2-3 months after initial treatment: a prospective trial in 905 patients with sleep-disordered breathing.

Authors:  Nikolaus C Netzer; János Juhász; Markus Hofmann; Kathrin Hohl; Kingman P Strohl; Thomas E A H Küpper
Journal:  Sleep Breath       Date:  2010-03-04       Impact factor: 2.816

2.  All APAPs Are Not Equivalent for the Treatment of Sleep Disordered Breathing: A Bench Evaluation of Eleven Commercially Available Devices.

Authors:  Kaixian Zhu; Gabriel Roisman; Sami Aouf; Pierre Escourrou
Journal:  J Clin Sleep Med       Date:  2015-07-15       Impact factor: 4.062

3.  Retrospective, nonrandomized controlled study on autoadjusting, dual-pressure positive airway pressure therapy for a consecutive series of complex insomnia disorder patients.

Authors:  Barry Krakow; Natalia D McIver; Victor A Ulibarri; Michael R Nadorff
Journal:  Nat Sci Sleep       Date:  2017-03-10