Auditory steady-state response evaluation of auditory thresholds in cochlear implant patients.

Mikael Ménard1, Stéphane Gallego, Eric Truy, Christian Berger-Vachon, John D Durrant, Lionel Collet.   

Abstract

The aims of this work were to characterize the electrophysiologic response obtained by measurement of the auditory steady-state response (ASSR) in patients with a cochlear implant (MXM Digisonic) and to study the relationship between the subjective thresholds of the implantees and those estimated using electrical auditory steady-state response (ASSR)-based objective audiometry. Five subjects were examined with the use of four carrier frequencies--600, 1000, 2000 and 3500 Hz--modulated at frequencies between 70 and 85Hz, a particular frequency of modulation being represented at a specific electrode (for each carrier frequency) as a particular pulse-width modulation frequency. The protocol consisted of testing output and thresholds for different overall pulse durations for several stimulus (pulse) intensities, rendering multiple threshold measures (in duration) for each subject tested. The non-linearity of response growth, as a function of duration, provided the basis for teasing apart physiologic response and electrical artefact in the suprathreshold recorded responses. Thresholds estimated with use of the electrical ASSR demonstrated reasonably good agreement with the subjective thresholds. The results obtained thus demonstrated the efficacy of the approach and are encouraging for further advances in cochlear implant applications.

Entities:  

Mesh:

Year:  2004        PMID: 15732381

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  5 in total

1.  Towards an optimal paradigm for intraoperative auditory nerve monitoring with auditory steady state responses.

Authors:  Stefan Rampp; Leonhard Rensch; Sebastian Simmermacher; Torsten Rahne; Christian Strauss; Julian Prell
Journal:  J Clin Monit Comput       Date:  2016-02-06       Impact factor: 2.502

2.  Electrically evoked auditory steady state responses in cochlear implant users.

Authors:  Michael Hofmann; Jan Wouters
Journal:  J Assoc Res Otolaryngol       Date:  2009-12-22

3.  The effect of the transducers on paediatric thresholds estimated with auditory steady-state responses.

Authors:  D Bakhos; H Vitaux; A Villeneuve; S Kim; E Lescanne; V Pigeon; J M Aoustin; P Bordure; J Galvin
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-09-02       Impact factor: 2.503

4.  Auditory steady state responses and cochlear implants: Modeling the artifact-response mixture in the perspective of denoising.

Authors:  Faten Mina; Virginie Attina; Yvan Duroc; Evelyne Veuillet; Eric Truy; Hung Thai-Van
Journal:  PLoS One       Date:  2017-03-28       Impact factor: 3.240

Review 5.  Intra-operative hearing monitoring methods in middle ear surgeries.

Authors:  Wei Ren; Fei Ji; Jialing Zeng; Hui Zhao
Journal:  J Otol       Date:  2017-02-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.