Literature DB >> 15723397

In vivo method for correcting transmit/receive nonuniformities with phased array coils.

Jinghua Wang1, Maolin Qiu, R Todd Constable.   

Abstract

Phased array coils are finding widespread applications in both the research and the clinical setting. However, intensity nonuniformities with such coils can reduce the potential benefits of these coils, particularly for applications such as tissue segmentation. In this work, a method is described for correcting the nonuniform signal response based on in vivo measures of both the transmission field of body coil and the reception sensitivity of phased array coils, separately. For a uniform phantom, the reception sensitivity can be calculated using both Bloch equations and transmission field maps. For a heterogeneous object such as a brain, a minimal contrast acquisition must be obtained to map the receiver nonuniformities. This transmit field/receiver sensitivity (TFRS) approach is compared with the standard methods of using the body coil to obtain a reference scan and low-pass filtering. The quantitative comparison results shows that the TFRS approach provides superior results in correcting intensity nonuniformities for a uniform phantom. This approach reduces the ratio between signal intensity SD of an image and its mean intensity from approximately 21% before correction to 13% after correction. Results are also shown demonstrating the utility of this approach in vivo with human brain images. The method is general and can be applied with most pulse sequences, any coil combination for transmission and reception, and in any anatomic region. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15723397     DOI: 10.1002/mrm.20377

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  50 in total

1.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

2.  Association between cardiovagal baroreflex sensitivity and baseline cerebral perfusion of the hippocampus.

Authors:  Jitanan Laosiripisan; Takashi Tarumi; Mitzi M Gonzales; Andreana P Haley; Hirofumi Tanaka
Journal:  Clin Auton Res       Date:  2015-08-18       Impact factor: 4.435

3.  Fractionated manganese-enhanced MRI.

Authors:  Nicholas A Bock; Fernando F Paiva; Afonso C Silva
Journal:  NMR Biomed       Date:  2008-06       Impact factor: 4.044

4.  Regional differences in the coupling of cerebral blood flow and oxygen metabolism changes in response to activation: implications for BOLD-fMRI.

Authors:  Beau M Ances; Oleg Leontiev; Joanna E Perthen; Christine Liang; Amy E Lansing; Richard B Buxton
Journal:  Neuroimage       Date:  2007-11-22       Impact factor: 6.556

5.  Effects of aging on cerebral blood flow, oxygen metabolism, and blood oxygenation level dependent responses to visual stimulation.

Authors:  Beau M Ances; Christine L Liang; Oleg Leontiev; Joanna E Perthen; Adam S Fleisher; Amy E Lansing; Richard B Buxton
Journal:  Hum Brain Mapp       Date:  2009-04       Impact factor: 5.038

6.  Evidence from high-altitude acclimatization for an integrated cerebrovascular and ventilatory hypercapnic response but different responses to hypoxia.

Authors:  Zachary M Smith; Erin Krizay; Rui Carlos Sá; Ethan T Li; Miriam Scadeng; Frank L Powell; David J Dubowitz
Journal:  J Appl Physiol (1985)       Date:  2017-07-13

7.  Age-related mapping of intracortical myelin from late adolescence to middle adulthood using T1 -weighted MRI.

Authors:  Christopher D Rowley; Manpreet Sehmbi; Pierre-Louis Bazin; Christine L Tardif; Luciano Minuzzi; Benicio N Frey; Nicholas A Bock
Journal:  Hum Brain Mapp       Date:  2017-04-30       Impact factor: 5.038

8.  Acetazolamide during acute hypoxia improves tissue oxygenation in the human brain.

Authors:  Kang Wang; Zachary M Smith; Richard B Buxton; Erik R Swenson; David J Dubowitz
Journal:  J Appl Physiol (1985)       Date:  2015-10-15

9.  T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

Authors:  Pierre-François Van de Moortele; Edwards J Auerbach; Cheryl Olman; Essa Yacoub; Kâmil Uğurbil; Steen Moeller
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

10.  Rapid 3D radiofrequency field mapping using catalyzed double-angle method.

Authors:  Dingxin Wang; Sven Zuehlsdorff; Andrew C Larson
Journal:  NMR Biomed       Date:  2009-10       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.