Literature DB >> 15720577

EOG correction: a comparison of four methods.

Rodney J Croft1, Jody S Chandler, Robert J Barry, Nicholas R Cooper, Adam R Clarke.   

Abstract

EOG correction is a class of techniques that account for ocular artifact in the electroencephalogram (EEG) by subtracting electrooculographic data from the EEG. The purpose of this study was to evaluate four of these correction techniques (Verleger, Gasser, & Mocks, 1982 [VGM]; Gratton, Coles, & Donchin, 1983 [GCD]; Semlitsch, Presslich, Schuster, & Anderer, 1986 [SPSA]; Croft & Barry, 2000 [CB]). Blinks, vertical eye movements (VEM), and horizontal eye movements (HEM) from 26 subjects were corrected using these techniques, and eye movement event-related potentials computed to aid validation. HEMs were corrected better by CB, VGM/GCD then SPSA, VEMs by CB, VGM/GCD then SPSA, and blinks by CB, SPSA, GCD and then VGM, with the advantage of CB substantial for blinks (eta2>.72), VEMs (eta2>.60), and HEMs (eta2>.27). It is argued that the CB procedure adequately accounts for ocular artifact in the EEG. Reasons for the limitations of the other procedures are discussed.

Entities:  

Mesh:

Year:  2005        PMID: 15720577     DOI: 10.1111/j.1468-8986.2005.00264.x

Source DB:  PubMed          Journal:  Psychophysiology        ISSN: 0048-5772            Impact factor:   4.016


  10 in total

1.  Disentangling gaze shifts from preparatory ERP effects during spatial attention.

Authors:  Steffan Kennett; José van Velzen; Martin Eimer; Jon Driver
Journal:  Psychophysiology       Date:  2007-01       Impact factor: 4.016

2.  Electromyographic activity in the EEG in Alzheimer's disease: noise or signal?

Authors:  Karin van der Hiele; Robert H A M Reijntjes; Alla A Vein; Rudi G J Westendorp; Mark A van Buchem; Eduard L E M Bollen; Huub A M Middelkoop; J Gert van Dijk
Journal:  Int J Alzheimers Dis       Date:  2011-03-29

3.  Hybrid EEG--Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal.

Authors:  Malik M Naeem Mannan; Shinjung Kim; Myung Yung Jeong; M Ahmad Kamran
Journal:  Sensors (Basel)       Date:  2016-02-19       Impact factor: 3.576

4.  Radiofrequency Electromagnetic Field Exposure and the Resting EEG: Exploring the Thermal Mechanism Hypothesis.

Authors:  Sarah P Loughran; Adam Verrender; Anna Dalecki; Catriona A Burdon; Kyoko Tagami; Joonhee Park; Nigel A S Taylor; Rodney J Croft
Journal:  Int J Environ Res Public Health       Date:  2019-04-28       Impact factor: 3.390

5.  Is Brain Dynamics Preserved in the EEG After Automated Artifact Removal? A Validation of the Fingerprint Method and the Automatic Removal of Cardiac Interference Approach Based on Microstate Analysis.

Authors:  Gabriella Tamburro; Pierpaolo Croce; Filippo Zappasodi; Silvia Comani
Journal:  Front Neurosci       Date:  2021-01-12       Impact factor: 4.677

6.  The Safety, Clinical, and Neurophysiological Effects of Intranasal Ketamine in Patients Who Do Not Respond to Electroconvulsive Therapy: Protocol for a Pilot, Open-Label Clinical Trial.

Authors:  Yuliya Knyahnytska; Reza Zomorrodi; Tyler Kaster; Daphne Voineskos; Alisson Trevizol; Daniel Blumberger
Journal:  JMIR Res Protoc       Date:  2022-01-17

7.  Combining EEG and eye tracking: identification, characterization, and correction of eye movement artifacts in electroencephalographic data.

Authors:  Michael Plöchl; José P Ossandón; Peter König
Journal:  Front Hum Neurosci       Date:  2012-10-09       Impact factor: 3.169

8.  The correction of eye blink artefacts in the EEG: a comparison of two prominent methods.

Authors:  Sven Hoffmann; Michael Falkenstein
Journal:  PLoS One       Date:  2008-08-20       Impact factor: 3.240

9.  Hybrid ICA-Regression: Automatic Identification and Removal of Ocular Artifacts from Electroencephalographic Signals.

Authors:  Malik M Naeem Mannan; Myung Y Jeong; Muhammad A Kamran
Journal:  Front Hum Neurosci       Date:  2016-05-03       Impact factor: 3.169

10.  Robust Single-Trial EEG-Based Authentication Achieved with a 2-Stage Classifier.

Authors:  Uladzislau Barayeu; Nastassya Horlava; Arno Libert; Marc Van Hulle
Journal:  Biosensors (Basel)       Date:  2020-09-13
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.