Compensation of magnetic field distortions from paramagnetic instruments by added diamagnetic material: measurements and numerical simulations.

Bernd Müller-Bierl1, Hansjörg Graf, Günter Steidle, Fritz Schick.   

Abstract

In minimally invasive procedures guided by magnetic resonance (MR) imaging instruments usually are made of titanium or titanium alloys (e.g., nitinol), because other more MR-compatible materials often cannot provide sufficient mechanical properties. Artifacts depending on susceptibility arise in MR images due to incorrect spatial encoding and intravoxel dephasing and thereby hamper the surgeon's view onto the region of interest. To overcome the artifact problem, compensation of the paramagnetic properties by diamagnetic coating or filling of the instruments has been proposed in the literature. We used a numerical modeling procedure to estimate the effect of compensation. Modeling of the perturbation of the static magnetic field close to the instruments reflects the underlying problem and is much faster and cost efficient than manufacturing prototypes and measuring artifact behavior of these prototypes in the MR scanner. A numerical model based on the decomposition of the susceptibility distribution in elementary dipoles was developed by us. The program code was written object oriented to allow for both maximum computational speed and minimum random access memory. We used System International units throughout the modeling for the magnetic field, allowing absolute quantification of the magnetic field disturbance. The field outside a simulated needlelike instrument, modeled by a paramagnetic cylinder (out of titan, chi =181.1) of length 8.0 mm and of diameter 1.0 mm, coated with a diamagnetic layer (out of bismuth, chi=-165.0) of thickness 0, 0.1, 0.2, 0.3, and 0.4 mm, was found to be best compensated if the cross-sectional area of the cylinder, multiplied by the absolute susceptibility value of the cylinder material, is equal to the cross-sectional area of the coating, multiplied by the absolute susceptibility value of the coating material. At the extremity of the coated cylinder an uncompensated field distortion was found to remain. We studied various tip shapes and geometries using our computational model: Suitable diamagnetic coating or filling of paramagnetic instruments clearly reduced tip artifacts and diminished the dependency of artifact size on orientation of the instrument with respect to B0 in the numerical studies. We verified the results of the simulations by measuring coated and uncoated titanium wires in a 1.5 T MR scanner.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15719957     DOI: 10.1118/1.1828674

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  Numerical simulations of intra-voxel dephasing effects and signal voids in gradient echo MR imaging using different sub-grid sizes.

Authors:  Bernd M Müller-Bierl; Hansjörg Graf; Philippe L Pereira; Fritz Schick
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

3.  Effect of spatial distribution of magnetic dipoles on Lamor frequency distribution and MR Signal decay--a numerical approach under static dephasing conditions.

Authors:  J Pintaske; B Müller-Bierl; F Schick
Journal:  MAGMA       Date:  2006-02-10       Impact factor: 2.310

4.  Computation of Magnetic Field Distortions and Impact on T2*-weighted MRI with Application to Magnetic Susceptibility Parameter Estimation.

Authors:  Corey E Cruttenden; Xiao-Hong Zhu; Wei Chen; Rajesh Rajamani
Journal:  Biomed Phys Eng Express       Date:  2018-06-14

5.  Minimal artifact actively shimmed metallic needles in MRI.

Authors:  Saikat Sengupta; Xinqiang Yan; Tamarya L Hoyt; Gary Drake; Anthony Gunderman; Yue Chen
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

6.  Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features.

Authors:  F Streitparth; T Walter; U Wonneberger; S Chopra; F Wichlas; M Wagner; K G Hermann; B Hamm; U Teichgräber
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

7.  Novel Composite Gold-Aluminum Electrode with Application to Neural Recording and Stimulation in Ultrahigh Field Magnetic Resonance Imaging Scanners.

Authors:  Corey E Cruttenden; Mahdi Ahmadi; Yi Zhang; Xiao-Hong Zhu; Wei Chen; Rajesh Rajamani
Journal:  Ann Biomed Eng       Date:  2021-04-21       Impact factor: 4.219

8.  Susceptibility artifacts induced by crowns of different materials with prepared teeth and titanium implants in magnetic resonance imaging.

Authors:  Xiaomeng Gao; Qianbing Wan; Qingping Gao
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.