Literature DB >> 15712980

Volar fixed-angle plating of the distal radius.

Dean W Smith1, Mark H Henry.   

Abstract

The treatment of unstable distal radius fractures continues to improve as better methods of skeletal fixation and soft-tissue management are developed. Apart from closed reduction and percutaneous pinning of simpler fracture patterns, the three main methods of management are external fixation, dorsal plating, and volar fixed-angle plating. Specific advantages of volar fixed-angle plating include stable fixed-angle support that permits early active wrist rehabilitation, direct fracture reduction, and fewer soft-tissue and tendon problems. Volar fixed-angle plating also avoids the complications often associated with external fixation and dorsal plating. Biomechanical data indicate that, when loaded to failure, volar fixed-angle plates have significant strength advantages over dorsal plating. Volar fixed-angle plating is advantageous in elderly osteopenic patients and for high-energy comminuted fractures and malunions requiring osteotomy.

Entities:  

Mesh:

Year:  2005        PMID: 15712980     DOI: 10.5435/00124635-200501000-00005

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  23 in total

1.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.

Authors:  Lindley B Wall; Michael D Brodt; Matthew J Silva; Martin I Boyer; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

2.  [Flexor tendon rupture after palmar osteosynthesis using a multidirectional fixed-angle plate].

Authors:  B Hohendorff; P Kurzen; A Boss
Journal:  Unfallchirurg       Date:  2006-11       Impact factor: 1.000

3.  Flexor tendon problems after volar plate fixation of distal radius fractures.

Authors:  Mehdi N Adham; Margaret Porembski; Christine Adham
Journal:  Hand (N Y)       Date:  2009-03-13

4.  Dacron--silicone prosthesis for the metacarpophalangeal and interphalangeal joints.

Authors:  J J Niebauer; R M Landry
Journal:  Hand       Date:  1971-03

5.  Surgical approach to bone healing in osteoporosis.

Authors:  Vito Pesce; Domenico Speciale; Giulio Sammarco; Silvio Patella; Antonio Spinarelli; Vittorio Patella
Journal:  Clin Cases Miner Bone Metab       Date:  2009-05

6.  Corrective osteotomy for deformity of the distal radius using a volar locking plate.

Authors:  Brett Peterson; Varun Gajendran; Robert M Szabo
Journal:  Hand (N Y)       Date:  2007-08-10

7.  Biomechanical evaluation of volar locking plates for distal radius fractures.

Authors:  Scott M Levin; Cory O Nelson; Jonathan D Botts; Glenn A Teplitz; Yong Kwon; Fred Serra-Hsu
Journal:  Hand (N Y)       Date:  2007-08-07

8.  The role of locking technology in the upper extremity.

Authors:  Siddharth B Joglekar; Asif M Ilyas
Journal:  J Hand Microsurg       Date:  2010-01-08

9.  The Effect of Radial Shaft Dorsal Screw Prominence in Volar Locking Plate Fixation of Distal Radius Fractures.

Authors:  Nicholas Pulos; Brent R DeGeorge; Alexander Y Shin; Marco Rizzo
Journal:  Hand (N Y)       Date:  2018-08-06

10.  Early Versus Late Motion Following Volar Plating of Distal Radius Fractures.

Authors:  David G Dennison; Charlene L Blanchard; Bassem Elhassan; Steven L Moran; Alexander Y Shin
Journal:  Hand (N Y)       Date:  2018-07-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.