Literature DB >> 15703920

Fractures of the distal tibia treated with closed reduction and minimally invasive plating.

T Krackhardt1, J Dilger, I Flesch, D Höntzsch, C Eingartner, K Weise.   

Abstract

INTRODUCTION: The treatment of fractures of the distal tibia can be problematical because of the thin soft-tissue covering. Bridging slide-insertion plate osteosynthesis is performed by indirect, axially correct reduction of the fracture and stabilization without opening the soft tissue at the fracture site. Stripping of the periosteum is thus avoided, the fragments remain integrated into the soft tissue, and healing occurs spontaneously by way of callus formation.
MATERIALS AND METHODS: Seventy-one patients treated by slide-insertion plate osteosynthesis were followed up over at least 2 years. As would be expected in this anatomical region, the proportion of C fractures and fractures with concomitant soft-tissue damage was high. The majority of patients were treated by application of an external fixator on the day of the accident; the definitive osteosynthesis with the slide-insertion plate was performed at a later date after healing of the soft tissues.
RESULTS: In 68 patients, fracture healing was achieved within 2 years. In 80% of the cases, the final X-ray follow-up showed no or tolerable axis deviations (<5 degrees) in the varus/valgus plane or in the recurvation/antecurvation plane. A deviation >10 degrees requiring a correcting osteotomy was found in only 1 patient. Postoperative complications were rare occurrences. Five patients required an additional cancellous bone graft to deal with inadequate bone healing. System-related complications (instability, malalignment) due to intraoperative technical errors only had to be corrected in revision operations in 2 patients.
CONCLUSION: Closed reduction and minimally invasive plating offers the combined advantages of minimal soft-tissue damage with stable fracture fixation.

Entities:  

Mesh:

Year:  2005        PMID: 15703920     DOI: 10.1007/s00402-004-0778-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  18 in total

1.  [Minimally invasive plate osteosynthesis of the distal tibia].

Authors:  T S Müller; C Sommer
Journal:  Oper Orthop Traumatol       Date:  2012-09       Impact factor: 1.154

Review 2.  [Management strategies in the first operative phase after long-bone injury of the lower extremity in multiple-injured patients. A systematic literature review].

Authors:  D Rixen; S Sauerland; H-J Oestern; B Bouillon
Journal:  Unfallchirurg       Date:  2005-10       Impact factor: 1.000

3.  Staged protocol in treatment of open distal tibia fracture: using lateral MIPO.

Authors:  Oog Jin Sohn; Dong Hwa Kang
Journal:  Clin Orthop Surg       Date:  2011-02-15

Review 4.  Plate fixation versus intramedullary nailing for displaced extra-articular distal tibia fractures: a system review.

Authors:  Bo Li; Yuehua Yang; Lei-Sheng Jiang
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

5.  Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures.

Authors:  T W Lau; F Leung; C F Chan; S P Chow
Journal:  Int Orthop       Date:  2007-06-16       Impact factor: 3.075

6.  Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

Authors:  Rakesh K Gupta; Rajesh Kumar Rohilla; Kapil Sangwan; Vijendra Singh; Saurav Walia
Journal:  Int Orthop       Date:  2009-10-10       Impact factor: 3.075

7.  Fractures of the distal tibia treated with polyaxial locking plating.

Authors:  Hong Gao; Chang-Qing Zhang; Cong-Feng Luo; Zu-Bin Zhou; Bing-Fang Zeng
Journal:  Clin Orthop Relat Res       Date:  2008-08-22       Impact factor: 4.176

8.  Treatment of Distal Lower Leg Fractures: Results with Fixed-Angle Plate Osteosynthesis.

Authors:  Maximilian Faschingbauer; Benjamin Kienast; Arndt P Schulz; Rudolf Vukelic; Jan Meiners
Journal:  Eur J Trauma Emerg Surg       Date:  2009-11-16       Impact factor: 3.693

9.  The direct lateral approach to the distal tibia and fibula: a single incision technique for distal tibial and pilon fractures.

Authors:  John E Femino; Tanawat Vaseenon
Journal:  Iowa Orthop J       Date:  2009

10.  Accuracy of Ultrasonography in Confirmation of Adequate Reduction of Distal Radius Fractures.

Authors:  Mehrdad Esmailian; Ehsan Haj Zargarbashi; Babak Masoumi; Mehdi Karami
Journal:  Emerg (Tehran)       Date:  2013
View more