Literature DB >> 1570143

Total hip revision arthroplasty. Prosthesis and cement removal techniques.

F B Gray1.   

Abstract

A modified technique for the removal of cemented total hip components and methylmethacrylate has been presented. This format utilizes manual tools and low-speed drills, reamers, and end mills. The advantages are safety, predictability, shorter learning curves, and cost effectiveness. Problems encountered with the dulling of manual tools used against methylmethacrylate are addressed by conversion to modular tools with readily replaceable working tips made of high-speed, hardened stainless steel. Safety and efficacy are facilitated by utilization of a step-cut technique of cement removal and fixed-point orientation at the distal cement column.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1570143

Source DB:  PubMed          Journal:  Orthop Clin North Am        ISSN: 0030-5898            Impact factor:   2.472


  3 in total

1.  Scanning electron microscopy investigation of PMMA removal by laser irradiation (Er:YAG) in comparison with an ultrasonic system and curettage in hip joint revision arthroplasty.

Authors:  Klaus Birnbaum; Norbert Gutknecht
Journal:  Lasers Med Sci       Date:  2010-03-31       Impact factor: 3.161

2.  Thermomechanical method for cement extraction in revision arthroplasty.

Authors:  M Ghanem; A Koenig; F Dehn; C-E Heyde; C Josten
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-18

3.  Risk of periprosthetic femur fracture after anterior cortical bone windowing: a mechanical analysis of short versus long cemented stems in pigs.

Authors:  Lance J Wilson; Corey J Richards; Dean Irvine; Armand Tillie; Ross W Crawford
Journal:  Acta Orthop       Date:  2011-11-09       Impact factor: 3.717