Literature DB >> 15685062

Radiographic comparison of two glenoid preparation techniques in total shoulder arthroplasty.

Istvan Szabo1, Florent Buscayret, T Bradley Edwards, Chantal Nemoz, Daniel P O'Connor, Pascal Boileau, Gilles Walch.   

Abstract

We compared the prevalence of periglenoid radiolucencies between two glenoid component preparation techniques used in total shoulder arthroplasties. Seventy-two consecutive patients with primary osteoarthritis had total shoulder arthroplasties using one prosthetic system with flat-back keeled polyethylene glenoid components. Thirty-seven shoulders had glenoid implants that were cemented after standard curettage preparation of the keel slot. Thirty-five shoulders had glenoid implants that were cemented after using bone compaction to prepare the keel slot. The immediate postoperative and 2-year postoperative radiographs were examined to evaluate the presence and progression of periglenoid radiolucencies. The curettage group had a higher rate (38%) of keel radiolucencies than the compaction group (11%) seen on the immediate postoperative radiographs. Both groups had progression of periglenoid radiolucencies with time. Progression of the radiolucent lines was worse in the curettage group 2 years after arthroplasty. Preparation of the glenoid component keel slot with the bone compaction technique seems to achieve better fixation of flat-back keeled polyethylene glenoid components in total shoulder arthroplasties.

Entities:  

Mesh:

Year:  2005        PMID: 15685062     DOI: 10.1097/01.blo.0000150322.93550.2f

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

1.  Clinical and radiological results of a cementless short stem shoulder prosthesis at minimum follow-up of two years.

Authors:  Marc Schnetzke; Sebastian Coda; Gilles Walch; Markus Loew
Journal:  Int Orthop       Date:  2015-04-23       Impact factor: 3.075

2.  Evaluation of thirty eight cemented pegged glenoid components with variable backside curvature: two-year minimum follow-up.

Authors:  Florence Dauzère; Marine Arboucalot; Julie Lebon; Fanny Elia; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2017-09-15       Impact factor: 3.075

3.  Glenoid vault perforation in total shoulder arthroplasty: Do we need computer guidance?

Authors:  Jennifer N Flynn; Malin Wijeratna; Matthew Evans; Steven Lee; David McD Taylor; Gregory A Hoy
Journal:  Shoulder Elbow       Date:  2019-11-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.