Literature DB >> 15684262

Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients.

Richard M Cooper1, John A Pacey, Michael J Bishop, Stuart A McCluskey.   

Abstract

PURPOSE: To evaluate a new videolaryngoscope and assess its ability to provide laryngeal exposure and facilitate intubation.
METHODS: Five centres, involving 133 operators and a total of 728 consecutive patients, participated in the evaluation of a new video-laryngoscope [GlideScope (GS)]. Many operators had limited or no previous GS experience. We collected information about patient demographics and airway characteristics, Cormack-Lehane (C/L) views and the ease of intubation using the GS. Failure was defined as abandonment of the technique.
RESULTS: Data from six patients were incomplete and were excluded. Excellent (C/L 1) or good (C/L 2) laryngeal exposure was obtained in 92% and 7% of patients respectively. In all 133 patients in whom both GS and direct laryngoscopy (DL) were performed, GS resulted in a comparable or superior view. Among the 35 patients with C/L grade 3 or 4 views by DL, the view improved to a C/L 1 view in 24 and a C/L 2 view in three patients. Intubation with the GS was successful in 96.3% of patients. The majority of the failures occurred despite a good or excellent glottic view.
CONCLUSIONS: GS laryngoscopy consistently yielded a comparable or superior glottic view compared with DL despite the limited or lack of prior experience with the device. Successful intubation was generally achieved even when DL was predicted to be moderately or considerably difficult. GS was abandoned in 3.7% of patients. This may reflect the lack of a formal protocol defining failure, limited prior experience or difficulty manipulating the endotracheal tube while viewing a monitor.

Entities:  

Mesh:

Year:  2005        PMID: 15684262     DOI: 10.1007/bf03027728

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  88 in total

1.  [Death due to (no) airway. Adverse events by out-of-hospital airway management?].

Authors:  S G Russo; W Zink; H Herff; C H R Wiese
Journal:  Anaesthesist       Date:  2010-10       Impact factor: 1.041

2.  [Unexpected expectable difficult airway : every anesthesia is different].

Authors:  A Schneider; B Grosse-Ophoff; B W Böttiger
Journal:  Anaesthesist       Date:  2010-05       Impact factor: 1.041

3.  [Implementation of the laryngeal tube for prehospital airway management: training of 1,069 emergency physicians and paramedics].

Authors:  R Schalk; T Auhuber; O Haller; L Latasch; S Wetzel; C F Weber; M Ruesseler; C Byhahn
Journal:  Anaesthesist       Date:  2012-01-25       Impact factor: 1.041

4.  The effect of stylet choice on the success rate of intubation using the GlideScope video laryngoscope in the emergency department.

Authors:  John C Sakles; Leah Kalin
Journal:  Acad Emerg Med       Date:  2012-01-24       Impact factor: 3.451

5.  Recognition and management of the difficult airway with special emphasis on the intubating LMA-Fastrach/whistle technique: a brief review with case reports.

Authors:  James M Rich
Journal:  Proc (Bayl Univ Med Cent)       Date:  2005-07

6.  Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-.

Authors:  Guen Seok Choi; Sang Il Park; Eun Ha Lee; Seok Hwa Yoon
Journal:  Korean J Anesthesiol       Date:  2010-12-31

7.  Airway Scope: early clinical experience in 405 patients.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  J Anesth       Date:  2008-02-27       Impact factor: 2.078

Review 8.  Optical and video laryngoscopes for emergency airway management.

Authors:  John C Sakles; Ross Rodgers; Samuel M Keim
Journal:  Intern Emerg Med       Date:  2008-02-15       Impact factor: 3.397

Review 9.  [Airway management].

Authors:  G Schälte; S Rex; D Henzler
Journal:  Anaesthesist       Date:  2007-08       Impact factor: 1.041

Review 10.  GlideScope video laryngoscopy use tracheal intubation in patients with ankylosing spondylitis: a series of four cases and literature review.

Authors:  Vahap Saricicek; Ayse Mizrak; Rauf Gul; Sitki Goksu; Mehmet Cesur
Journal:  J Clin Monit Comput       Date:  2013-09-18       Impact factor: 2.502