Literature DB >> 15678258

Vascular complications of the intra-aortic balloon counterpulsation.

Jirí Mand'ák1, Vladimír Lonský, Jan Dominik, Pavel Zácek.   

Abstract

From September 1994 to December 2002, 6,274 cardiosurgery operations were performed at the Department of Cardiac Surgery, University Hospital, Hradec Kralove, Czech Republic. Intra-aortic balloon counterpulsation (IABP) was applied in 192 cases (3.1%). From this group of 192 counterpulsated patients 103 were successfully treated (53.6%); 89 counterpulsated patients (46.4%) died from the surgical procedure (30-day mortality rate). In 5 cases (2.6%) from the group of 192, the IABP was introduced before the operation. Ischemic changes of the limb were observed in 11 cases (5.7%). Significant bleeding occurred at the site of puncture in 6 cases (3.1%). Dissection of the femoral and iliac arteries was found in 2 patients (1.0%), perforation of the iliac artery in 1 case (0.5%). In 2 cases (1.0%) the balloon was led into the venous system. In case report No. 1 an introduction of the balloon under a sclerotic plaque of the descending aorta and iliac artery is described. In case report No. 2 a placement of the balloon in the venous bloodstream is reported.

Entities:  

Mesh:

Year:  2005        PMID: 15678258     DOI: 10.1177/000331970505600109

Source DB:  PubMed          Journal:  Angiology        ISSN: 0003-3197            Impact factor:   3.619


  5 in total

Review 1.  [Ultrasound diagnosis of vascular complications following transfemoral puncture].

Authors:  D A Clevert; R Kubale; T I Strautz; P M Flach; C Trumm; R T Hoffmann; M Reiser
Journal:  Radiologe       Date:  2006-07       Impact factor: 0.635

2.  The length of the aorta from the subclavian artery to the renal artery based on computed tomographic measurements in Japanese adults.

Authors:  Tsuguo Igari
Journal:  J Artif Organs       Date:  2006-12-21       Impact factor: 1.731

3.  Imaging of mechanical cardiac assist devices.

Authors:  Daniel Ginat; Howard Todd Massey; Shweta Bhatt; Vikram S Dogra
Journal:  J Clin Imaging Sci       Date:  2011-05-02

Review 4.  Diagnostic vascular ultrasonography with the help of color Doppler and contrast-enhanced ultrasonography.

Authors:  Johannes Rübenthaler; Maximilian Reiser; Dirk-André Clevert
Journal:  Ultrasonography       Date:  2016-08-12

5.  Intra-Aortic Balloon Pump Entrapment in a Nonatherosclerotic Common Iliac Artery.

Authors:  Feridoun Sabzi; Abdol Hamid Zokaei; Abdol Rasoul Moloudi; Samsam Dabiri
Journal:  Open J Cardiovasc Surg       Date:  2011-09-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.