Literature DB >> 17171407

The length of the aorta from the subclavian artery to the renal artery based on computed tomographic measurements in Japanese adults.

Tsuguo Igari1.   

Abstract

To estimate the length of the aorta from the subclavian artery to the renal artery in Japanese adults, its length was measured on computed tomographic (CT) images. Data from a total of 110 patients without aortic or aortic valvular diseases (54 men, 56 women) who had undergone 7-mm-slice-interval CT examination of the entire aorta was analyzed in this study. The length of the aorta was found to be 214.1 +/- 20.7 mm and showed a positive correlation with height (r = 0.664). Especially, the length of the aorta in male patients was correlated with body mass, i.e., height, weight, and body surface area. From these results, it appears that the majority of commercially available intra-aortic balloon catheters are too long for use in the Japanese population. It is concluded that a shorter, more suitable catheter should be made available for safe use in Japanese patients.

Entities:  

Mesh:

Year:  2006        PMID: 17171407     DOI: 10.1007/s10047-006-0346-z

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  17 in total

1.  Acute ischemic hepatic failure resulting from intraaortic balloon pump malposition.

Authors:  H Shin; R Yozu; T Sumida; S Kawada
Journal:  Eur J Cardiothorac Surg       Date:  2000-04       Impact factor: 4.191

2.  Compartment syndrome from balloon pump.

Authors:  C A Velez; J Kahn
Journal:  Catheter Cardiovasc Interv       Date:  2000-10       Impact factor: 2.692

3.  Vascular complications of the intra-aortic balloon counterpulsation.

Authors:  Jirí Mand'ák; Vladimír Lonský; Jan Dominik; Pavel Zácek
Journal:  Angiology       Date:  2005 Jan-Feb       Impact factor: 3.619

Review 4.  Basic principles of the intraaortic balloon pump and mechanisms affecting its performance.

Authors:  Theodoros G Papaioannou; Christodoulos Stefanadis
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

5.  Vascular complications related to intraaortic balloon counterpulsation: an analysis of ten years experience.

Authors:  T Busch; H Sîrbu; D Zenker; H Dalichau
Journal:  Thorac Cardiovasc Surg       Date:  1997-04       Impact factor: 1.827

6.  Usefulness of the low profile "True 8" intra-aortic balloon pumping catheter for preventing limb lschemia.

Authors:  S Kuki; K Taniguchi; T Masai; K Yoshida; K Yamamoto; H Matsuda
Journal:  ASAIO J       Date:  2001 Nov-Dec       Impact factor: 2.872

7.  Ischaemic complications with intra-aortic balloon counter-pulsation: incidence and management.

Authors:  H Sirbu; T Busch; I Aleksic; M Friedrich; H Dalichau
Journal:  Cardiovasc Surg       Date:  2000-01

8.  Vascular complications of intra-aortic balloon insertion in patients undergoing coronary reavscularization: analysis of 911 cases.

Authors:  Zile Singh Meharwal; Naresh Trehan
Journal:  Eur J Cardiothorac Surg       Date:  2002-04       Impact factor: 4.191

9.  Intraaortic balloon pumping in patients requiring cardiac operations. Risk analysis and long-term follow-up.

Authors:  K S Naunheim; M T Swartz; D G Pennington; A C Fiore; L R McBride; P S Peigh; M G Barnett; K J Vaca; G C Kaiser; V L Willman
Journal:  J Thorac Cardiovasc Surg       Date:  1992-12       Impact factor: 5.209

10.  Vascular complications of the intra-aortic balloon pump.

Authors:  D J Mackenzie; W H Wagner; D A Kulber; R L Treiman; D V Cossman; R F Foran; J L Cohen; P M Levin
Journal:  Am J Surg       Date:  1992-11       Impact factor: 2.565

View more
  2 in total

1.  Journal of Artificial Organs 2006: the year in review.

Authors:  Y Sawa; T Horiuchi; A Kishida; T Masuzawa; M Nishimura; E Tatsumi; Y Tomizawa; H Watanabe
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

2.  Fixed-Distance Model for Balloon Placement During Fluoroscopy-Free Resuscitative Endovascular Balloon Occlusion of the Aorta in a Civilian Population.

Authors:  Pierre Pezy; Alexandros N Flaris; Nicolas J Prat; François Cotton; Peter W Lundberg; Jean-Louis Caillot; Jean-Stéphane David; Eric J Voiglio
Journal:  JAMA Surg       Date:  2017-04-01       Impact factor: 14.766

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.