STATEMENT OF PROBLEM: There is little information about the deflection fatigue of clasps in relation to stress distribution.
PURPOSE: The aim of this study was to investigate the fatigue resistance and permanent deformation of cast clasps made of titanium and other dental alloys and to relate the fatigue resistance with the calculated stress values.
MATERIAL AND METHODS: Twenty-five Ti-6Al-7Nb, 25 Co-Cr, and 15 Type IV gold alloy clasps were subjected to cyclic deflection of preset values of 0.25 mm, 0.50 mm, or 0.75 mm, for 10 6 cycles (n = 14). Finite element models were created to calculate principal stresses within the specimens. Fatigue life, retentive force, and permanent deformation were recorded, and the fracture locations were determined microscopically. The results were characterized in relation to the stress within the clasps. One-way analysis of variance and Tamhane's post-hoc tests were used to compare the results of the 9 material-deflection groups (alpha=.05).
RESULTS: Ti-6Al-7Nb clasps exhibited significantly less permanent deformation than the other clasps under relatively greater deflections, indicating better adaptation to the tooth surface. However, the fatigue life of the Ti-6Al-7Nb clasps under 0.75-mm deflection, with the stress above the alloy's 0.2% yield strength, was significantly shorter than those under smaller deflections. The gold clasps showed significantly longer fatigue life than the other clasps under the 0.50-mm deflection. High-stress areas within the fatigue clasp specimens coincided with the fracture locations. The probabilities of fatigue fracture and permanent deformation were closely related to the material strengths and the preset deflections.
CONCLUSION: To minimize fatigue failures, the cast clasp should be designed with consideration of the stresses distributions within the clasps.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15674231     DOI: 10.1016/j.prosdent.2004.11.011

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  The effect of disinfecting solutions on bending properties and weight changes of Co-Cr and Ti-6Al-7Nb alloys for dentures.

Authors:  Triantafillos Papadopoulos; Gregory Polyzois; Athena Tapanli; Maria Frangou
Journal:  Odontology       Date:  2011-01-27       Impact factor: 2.634

2.  Comparison of joint designs for laser welding of cast metal plates and wrought wires.

Authors:  Yasuko Takayama; Rie Nomoto; Hiroyuki Nakajima; Chikahiro Ohkubo
Journal:  Odontology       Date:  2011-11-12       Impact factor: 2.634

3.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

4.  Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps.

Authors:  Sherif Aly Sadek; Wessam Mohamed Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-06-07

5.  Performance of Graphene-Based and Polyether-Ether-Ketone Polymers as Removable Partial Denture Esthetic Clasp Materials after Cyclic Fatigue.

Authors:  Mostafa Omran Hussein
Journal:  Polymers (Basel)       Date:  2022-07-23       Impact factor: 4.967

6.  Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses?

Authors:  Danka Micovic; Felicitas Mayinger; Sebastian Bauer; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-07       Impact factor: 3.573

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.