Literature DB >> 15674158

Is noninvasive hemodynamic monitoring appropriate for the elderly critically injured patient?

Carlos V R Brown1, William C Shoemaker, Charles C J Wo, Linda Chan, Demetrios Demetriades.   

Abstract

BACKGROUND: Noninvasive hemodynamic monitoring in critically ill patients using bioimpedance technology has been shown to be a reliable alternative to invasive thermodilution techniques. However, there have been some concerns that the bioimpedance method may be unreliable in elderly patients with an atherosclerotic and rigid thoracic aorta. The purpose of the present study was to evaluate the effect of age on the reliability of noninvasive bioimpedance technology in measuring cardiac index.
METHODS: This is a retrospective analysis of prospectively collected data in critically injured patients admitted to the surgical intensive care unit. All patients had simultaneous measurement using thermodilution cardiac index (TDCI) and bioimpedance cardiac index (BICI). The population was divided into three age groups (<55 years, 55-70 years, and >70 years). The correlation between TDCI and BICI was calculated for each age group.
RESULTS: There were 1,138 simultaneous measurements of TDCI and BICI in 285 patients. The BICI correlated well with TDCI in all three age groups (r = 0.82 for group <55 years, r = 0.87 for group 55-70 years, and r = 0.80 for group >70 years).
CONCLUSION: Noninvasive cardiac index monitoring in elderly patients is reliable and correlates well with standard thermodilution techniques.

Entities:  

Mesh:

Year:  2005        PMID: 15674158     DOI: 10.1097/01.ta.0000105990.05074.4a

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  4 in total

Review 1.  Using video audit to improve trauma resuscitation--time for a new approach.

Authors:  Mark Fitzgerald; Rob Gocentas; Linas Dziukas; Peter Cameron; Colin Mackenzie; Nathan Farrow
Journal:  Can J Surg       Date:  2006-06       Impact factor: 2.089

2.  Non-invasive cardiac output monitoring device "ICON" in trauma patients: a feasibility study.

Authors:  Matthias Kuster; Tobias Haltmeier; Aristomenis Exadaktylos; Beat Schnüriger
Journal:  Eur J Trauma Emerg Surg       Date:  2018-07-16       Impact factor: 3.693

3.  Non-invasive hemodynamic monitoring in trauma patients.

Authors:  Matthias Kuster; Aristomenis Exadaktylos; Beat Schnüriger
Journal:  World J Emerg Surg       Date:  2015-03-08       Impact factor: 5.469

4.  Design and Implementation of a Portable Impedance Cardiography System for Noninvasive Stroke Volume Monitoring.

Authors:  Hassan Yazdanian; Amin Mahnam; Mehdi Edrisi; Morteza Abdar Esfahani
Journal:  J Med Signals Sens       Date:  2016 Jan-Mar
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.