Sonographic measurement of the inferior vena cava as a marker of blood loss.

Matthew Lyon1, Michael Blaivas, Larry Brannam.   

Abstract

UNLABELLED: Detecting and monitoring blood loss in trauma patients can often be challenging when an obvious source of hemorrhage is not readily seen.
OBJECTIVE: To provide a noninvasive measurement of circulating blood volume and of drop therein by measuring the change in the inferior vena cava diameter (IVCd) in relationship to blood loss.
METHODS: This was a prospective observational study on blood donors at a donation center. The IVCd, both during inspiration (IVCi) and during expiration (IVCe), was measured in volunteers both before and after blood donation of 450 mL. All actual blood donors aged 18 years and older were eligible for enrollment. Persons who were younger than 18 years, who declined to participate in the study, or who did not meet blood center criteria for blood donation were excluded. All examinations were performed in the supine position with the ultrasound transducer placed in a subxyphoid location. Sagittal sections of the IVC behind the liver were imaged and the maximal diameter of the IVCe and the minimal diameter of the IVCi were measured. Statistical analysis included test for normality, paired t test, and correlation analysis.
RESULTS: A total of 31 volunteers (18 male) with a mean age of 49.5 years (range, 18-73) were studied. The mean IVCe before blood donation was 17.4 mm (95% CI, 15.2-19.7 mm) and after blood donation was 11.9 mm (95% CI, 10.3-13.6 mm). The mean IVCi before blood donation was 13.3 mm (95% CI, 11.3-15.3 mm), but after blood donation was 8.13 mm (95% CI, 6.7-9.6 mm). The difference between IVCe before and after blood donation (dIVCe) was 5.5 mm (95% CI, 4.3-6.3 mm) yielding a P < .0001. The difference between IVCi before and after donation (dIVCi) was 5.16 mm (95% CI, 4.2-5.9 mm) yielding a P < .0001. The dIVCe and the dIVCi were closely correlated ( r = 0.83). Similarly, the pre-IVCe correlated well to the post-IVCe ( r = 0.74) and the pre-IVCi correlated well to the post-IVCi ( r = 0.75).
CONCLUSIONS: Our data indicates that the measurement of the IVC diameter is a reliable indicator of blood loss, even in small amounts of 450 mL. On average, there was about a 5-mm decrease in both the IVCe and IVCi after donation of 450 mL of blood. The measurement of the IVCe may be an important addition to the ultrasonographic evaluation of trauma and other potentially volume-depleted patients.

Entities:  

Mesh:

Year:  2005        PMID: 15672337     DOI: 10.1016/j.ajem.2004.01.004

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  42 in total

1.  Portable ultrasonography in mass casualty incidents: The CAVEAT examination.

Authors:  Stanislaw Peter Stawicki; James M Howard; John P Pryor; David P Bahner; Melissa L Whitmill; Anthony J Dean
Journal:  World J Orthop       Date:  2010-11-18

2.  Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage.

Authors:  Riccardo Moretti; Barbara Pizzi
Journal:  Neurocrit Care       Date:  2010-08       Impact factor: 3.210

3.  Echocardiographic Inferior Vena Cava Measurement As An Alternative to Central Venous Pressure Measurement in Neonates.

Authors:  Muzamil Mustafa Mugloo; Seema Malik; Rubeena Akhtar
Journal:  Indian J Pediatr       Date:  2017-06-21       Impact factor: 1.967

4.  Spectral analysis of finger photoplethysmographic waveform variability in a model of mild to moderate haemorrhage.

Authors:  Paul M Middleton; Gregory S H Chan; Emma O'Lone; Elizabeth Steel; Rebecca Carroll; Branko G Celler; Nigel H Lovell
Journal:  J Clin Monit Comput       Date:  2008-10-11       Impact factor: 2.502

5.  Ultrasound imaging method for internal jugular vein measurement and estimation of circulating blood volume.

Authors:  Kun Qian; Takehiro Ando; Kensuke Nakamura; Hongen Liao; Etsuko Kobayashi; Naoki Yahagi; Ichiro Sakuma
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-18       Impact factor: 2.924

6.  Use of bedside ultrasound to assess degree of dehydration in children with gastroenteritis.

Authors:  Lei Chen; Allen Hsiao; Melissa Langhan; Antonio Riera; Karen A Santucci
Journal:  Acad Emerg Med       Date:  2010-10       Impact factor: 3.451

Review 7.  Portable ultrasound in disaster triage: a focused review.

Authors:  S M Wydo; M J Seamon; S W Melanson; P Thomas; D P Bahner; S P Stawicki
Journal:  Eur J Trauma Emerg Surg       Date:  2015-02-11       Impact factor: 3.693

8.  Ultrasound measurements of the caudal vena cava before and after blood donation in 9 greyhound dogs.

Authors:  Kristen A Marshall; Elizabeth J Thomovsky; Aimee C Brooks; Paula A Johnson; Chee Kin Lim; Hock Gan Heng
Journal:  Can Vet J       Date:  2018-09       Impact factor: 1.008

9.  The Correlation Between Inferior Vena Cava Diameter Measured by Ultrasonography and Central Venous Pressure.

Authors:  Hans Vaish; Virendra Kumar; Rama Anand; Viswas Chhapola; Sandeep Kumar Kanwal
Journal:  Indian J Pediatr       Date:  2017-09-04       Impact factor: 1.967

10.  Bedside emergency cardiac ultrasound in children.

Authors:  Stephanie J Doniger
Journal:  J Emerg Trauma Shock       Date:  2010-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.