Literature DB >> 15665233

Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint.

K Honda1, Y Arai, M Kashima, Y Takano, K Sawada, K Ejima, K Iwai.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the usefulness of the limited cone-beam X-ray CT (3DX) (Morita Co., Japan) in measuring the thickness of the roof of the glenoid fossa (RGF) of the temporomandibular joint (TMJ).
MATERIALS AND METHODS: Twenty-one TMJs removed at autopsy from 21 cadavers were investigated macroscopically using dissection and 3DX imaging. A Digimatic Outside Micrometer and a 3DX-image tool were used to measure the minimum thickness of the RGF. Multiple measurements were made to identify the thinnest area. Once the thinnest areas had been identified, three linear measurements were made and the average value was used for statistical analysis.
RESULTS: The average macroscopic examination measurement was 1.37 mm (range 0.55-3.6 mm) and the average 3DX image measurement was 1.22 mm (range: 0.51-3.0 mm). There was no significant difference between these two groups using the Mann-Whitney U-test (P < 0.05). The Spearman's correlation coefficient by rank between these two groups was r = 0.93(P < 0.001).
CONCLUSION: These results suggest that bone thickness measurements of the RGF by 3DX imaging was effective.

Entities:  

Mesh:

Year:  2004        PMID: 15665233     DOI: 10.1259/dmfr/54316470

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  18 in total

1.  Oral Implant Imaging: A Review.

Authors:  Sarika Gupta; Neelkant Patil; Jitender Solanki; Ravinder Singh; Sanjeev Laller
Journal:  Malays J Med Sci       Date:  2015 May-Jun

2.  Comparison of periodontal evaluation by cone-beam computed tomography, and clinical and intraoral radiographic examinations.

Authors:  Wenjian Zhang; Shazia Rajani; Bing-Yan Wang
Journal:  Oral Radiol       Date:  2017-08-01       Impact factor: 1.852

3.  Effect of internal derangements and degenerative bone changes on the minimum thickness of the roof of the glenoid fossa in temporomandibular joint.

Authors:  Damla Soydan; Serap Doğan; Emin Murat Canger; Aykağan Coşgunarslan; Ibrahim Ethem Akgün; Hatice Cansu Kış
Journal:  Oral Radiol       Date:  2019-01-28       Impact factor: 1.852

4.  Correlation of mandibular impacted tooth and bone morphology determined by cone beam computed topography on a premise of third molar operation.

Authors:  M A Momin; K Matsumoto; K Ejima; R Asaumi; T Kawai; Y Arai; K Honda; T Yosue
Journal:  Surg Radiol Anat       Date:  2012-11-13       Impact factor: 1.246

5.  Relationship between the thickness of the roof of glenoid fossa, condyle morphology and remaining teeth in asymptomatic European patients based on cone beam CT data sets.

Authors:  K Ejima; D Schulze; A Stippig; K Matsumoto; D Rottke; K Honda
Journal:  Dentomaxillofac Radiol       Date:  2012-09-20       Impact factor: 2.419

6.  Development and Validation of Novel Three-Dimensional Craniofacial Landmarks on Cone-Beam Computed Tomography Scans.

Authors:  Denise K Liberton; Payal Verma; Anthony Contratto; Janice S Lee
Journal:  J Craniofac Surg       Date:  2019-10       Impact factor: 1.046

7.  Evaluation of the nasopalatine canal and variations with cone-beam computed tomography.

Authors:  Meryem Etoz; Yıldıray Sisman
Journal:  Surg Radiol Anat       Date:  2014-02-02       Impact factor: 1.246

8.  [Comparison of three-dimensional position on cone beam computed tomography of temporomandibular joint osteoarthrosis].

Authors:  Li Xiaomin; Yang Xiaoyu; Chen Yifan; Bao Lijie
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2015-04

9.  Precision of cephalometric landmark identification: cone-beam computed tomography vs conventional cephalometric views.

Authors:  John B Ludlow; Maritzabel Gubler; Lucia Cevidanes; André Mol
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-09       Impact factor: 2.650

10.  Assessing joint space and condylar position in the people with normal function of temporomandibular joint with cone-beam computed tomography.

Authors:  Zahra Dalili; Nasim Khaki; Seyed Javad Kia; Fatemeh Salamat
Journal:  Dent Res J (Isfahan)       Date:  2012-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.