Literature DB >> 15662307

Surface-gradient cross-linked polyethylene acetabular cups: oxidation resistance and wear against smooth and rough femoral balls.

Fu-Wen Shen1, Harry McKellop.   

Abstract

Two methods were developed and evaluated for cross-linking the bearing surface of a polyethylene acetabular cup to a limited depth, in order to improve its resistance to wear without degrading the mechanical properties of the bulk of the component. In the first method, low-energy electron beams were used to cross-link only the bearing surface of the cups to a maximum depth of about 2 mm. The cups then were annealed at 100 degrees C in vacuum for 3 or 6 days to reduce the residual free radicals, and the resultant resistance to oxidation was compared by artificially aging the cups at 80 degrees C in air. Chemically cross-linked surface layers were produced by coating the bearing surfaces of the cups with a thin layer of polyethylene powder mixed with 1% weight peroxide, and compressing them at 6.9 MPa (1000 psi) and 170 degrees C. This resulted in a cross-linked surface layer that extended about 3 mm deep, with a gradual transition to conventional (noncross-linked) polyethylene in the bulk of the implant. In hip simulator wear tests with highly polished (implant quality) femoral balls, both types of surface cross-linking were found to improve markedly the wear resistance of the acetabular cups. In tests with roughened femoral balls, the wear rates were much higher and were comparable to those obtained with similarly roughened balls against noncross-linked polyethylene cups in a previous study, indicating that the full benefit of cross-linking may not be realized under conditions of severe third-body abrasion. Nevertheless, these results show a promising approach for optimizing the wear resistance and the bulk mechanical properties of polyethylene components in total joint arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15662307

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

Review 1.  [Biomechanical aspects of revision components for knee arthroplasty].

Authors:  E Steinhauser; R Burgkart; L Gerdesmeyer
Journal:  Orthopade       Date:  2006-02       Impact factor: 1.087

Review 2.  Strategies and applications for incorporating physical and chemical signal gradients in tissue engineering.

Authors:  Milind Singh; Cory Berkland; Michael S Detamore
Journal:  Tissue Eng Part B Rev       Date:  2008-12       Impact factor: 6.389

3.  Scratching vulnerability of conventional vs highly cross-linked polyethylene liners because of large embedded third-body particles.

Authors:  Anneliese D Heiner; Alison L Galvin; John Fisher; John J Callaghan; Thomas D Brown
Journal:  J Arthroplasty       Date:  2011-11-23       Impact factor: 4.757

4.  Sliding direction dependence of polyethylene wear for metal counterface traverse of severe scratches.

Authors:  Liam P Glennon; Thomas E Baer; James A Martin; William D Lack; Thomas D Brown
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

Review 5.  Material Science in Cervical Total Disc Replacement.

Authors:  Martin H Pham; Vivek A Mehta; Alexander Tuchman; Patrick C Hsieh
Journal:  Biomed Res Int       Date:  2015-10-07       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.