Literature DB >> 15660803

Coronary sinus lead extraction in the era of cardiac resynchronization therapy: single center experience.

Babak Kasravi1, Serge Tobias, Mary J Barnes, John C Messenger.   

Abstract

As the number of coronary sinus (CS) lead implantations for cardiac resynchronization therapy increases so will the need for extraction of these leads. The safety of extraction of leads from the branches of the CS has not been reported. We reviewed our database of patients undergoing pacemaker lead extraction from January 2002 through February 2004 at our institution. Of 149 patients referred for lead extraction, 14 (9%) had a biventricular device. The indications for lead extraction were infection, lead malfunction, and exit block. The duration of CS lead implants ranged between 2 and 43 months (mean 17 months). All 14 CS leads were removed successfully using nonsurgical lead extraction techniques. Three leads that were in place the longest (> or =27 months) were removed via the femoral vein approach due to fibrous attachment of the CS lead body to the other pacemaker leads. The leads were structurally intact and without any significant fibrosis of their tips upon visual inspection. There were no major complications of CS laceration, hypotension, pericardial effusion, or excessive blood loss associated with any of the extraction procedures. CS leads were removed safely, successfully and with relative ease based on our experience in this small cohort of patients.

Entities:  

Mesh:

Year:  2005        PMID: 15660803     DOI: 10.1111/j.1540-8159.2005.09353.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Outcomes and predictors of difficulty with coronary sinus lead removal.

Authors:  Seth Sheldon; Paul A Friedman; David L Hayes; Michael J Osborn; Yong-Mei Cha; Robert F Rea; Samuel J Asirvatham
Journal:  J Interv Card Electrophysiol       Date:  2012-05-15       Impact factor: 1.900

2.  3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy.

Authors:  Cristiana Corsi; Corrado Tomasi; Dario Turco; Massimo Margheri; Claudio Lamberti; Stefano Severi
Journal:  Med Biol Eng Comput       Date:  2011-06-29       Impact factor: 2.602

3.  Unexpected challenging case of coronary sinus lead extraction.

Authors:  Luca Bontempi; Donatella Tempio; Raffaella De Vito; Manuel Cerini; Francesca Salghetti; Niccolò Dasseni; Clara Villa; Abdallah Raweh; Lorenza Inama; Francesca Vassanelli; Mario Luzi; Antonio Curnis
Journal:  World J Clin Cases       Date:  2017-02-16       Impact factor: 1.337

4.  Safety and effectiveness of coronary sinus leads extraction - single high-volume centre experience.

Authors:  Andrzej W Kutarski; Wojciech Jacheć; Łukasz Tułecki; Konrad Tomków; Paweł Stefańczyk; Wojciech Borzęcki; Dorota Nowosielecka; Marek Czajkowski; Maciej Polewczyk; Anna Polewczyk
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-09-18       Impact factor: 1.426

  4 in total