Literature DB >> 1565691

A cone-beam tomography algorithm for orthogonal circle-and-line orbit.

G L Zeng1, G T Gullberg.   

Abstract

A cone-beam algorithm which provides a practical implementation of B D Smith's cone-beam inversion formula is presented. For a cone-beam vertex orbit consisting of a circle and an orthogonal line. This geometry is easy to implement in a SPECT system, and it satisfies the cone-beam data sufficiency condition. The proposed algorithm is in the form of a convolution-back projection, and requires a pre-filtering procedure. Computer simulations show a reduction of the artifacts that are found with the Feldkamp algorithm where the cone-beam vertex orbit is a circle.

Entities:  

Mesh:

Year:  1992        PMID: 1565691     DOI: 10.1088/0031-9155/37/3/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Exact Weighted-FBP Algorithm for Three-Orthogonal-Circular Scanning Reconstruction.

Authors:  Hongli Hu; Jianzhou Zhang
Journal:  Sensors (Basel)       Date:  2009-06-12       Impact factor: 3.576

2.  A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.

Authors:  Konstantin Nikolaou; Thomas Flohr; Karl Stierstorfer; Christoph R Becker; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2004-11-20       Impact factor: 5.315

4.  Three-pinhole collimator to improve axial spatial resolution and sensitivity in pinhole SPECT.

Authors:  Christian Vanhove; Michel Defrise; Tony Lahoutte; Axel Bossuyt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11-14       Impact factor: 9.236

5.  Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.

Authors:  J Webster Stayman; Sarah Capostagno; Grace J Gang; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-02

6.  A new reconstruction strategy for image improvement in pinhole SPECT.

Authors:  Tsutomu Zeniya; Hiroshi Watabe; Toshiyuki Aoi; Kyeong Min Kim; Noboru Teramoto; Takuya Hayashi; Antti Sohlberg; Hiroyuki Kudo; Hidehiro Iida
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-17       Impact factor: 9.236

7.  An efficient estimation method for reducing the axial intensity drop in circular cone-beam CT.

Authors:  Lei Zhu; Jared Starman; Rebecca Fahrig
Journal:  Int J Biomed Imaging       Date:  2008-10-08

8.  Circle plus partial helical scan scheme for a flat panel detector-based cone beam breast X-ray CT.

Authors:  Dong Yang; Ruola Ning; Weixing Cai
Journal:  Int J Biomed Imaging       Date:  2009-12-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.