Literature DB >> 15654576

Does iodine concentration affect the diagnostic efficacy of biphasic spiral CT in patients with hepatocellular carcinoma?

A Marchianò1, C Spreafico, R Lanocita, L Frigerio, G Di Tolla, G Patelli, F Garbagnati, F Heiman, P Taroni, B Damascelli.   

Abstract

BACKGROUND: We investigated the effect of iodinated contrast medium concentration on increased neoplastic lesion enhancement and its direct relation to diagnostic efficacy in biphasic spiral computed tomography for detection of hepatocellular carcinoma.
METHODS: A pilot, single-center, randomized, double-blind, crossover, comparative study was performed and included 22 participants. Each patient underwent two separate biphasic contrast-enhanced spiral computed tomographic examinations. Scans were performed with iomeprol containing 400 (iomeprol 400) or 300 (iomeprol 300) mg of iodine per milliliter (Iomeron, Bracco Imaging SpA, Milan, Italy) with a 2- to 12-day window scan; patients were given an equal total dose of 45 g of iodine at a fixed injection rate of 4 mL/s. Comparison included assessment of quantitative and qualitative parameters.
RESULTS: Lesion density and lesion-to-liver contrast increased more markedly with the higher concentration of contrast medium during the arterial phase (p = 0.0016 and 0.0005, respectively). There was no significant difference in any parameter between the two concentrations during the portal phase. Number of lesions detected during the arterial phase increased from 37 with iomeprol 300 to 42 with iomeprol 400; in the portal phase, the respective numbers were 34 and 36.
CONCLUSION: Even though a small number of patients was examined, our study suggests that, in patients with cirrhosis, an increased concentration of iodine improves liver-to-lesion contrast and may improve the detection of hepatocellular carcinoma.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15654576     DOI: 10.1007/s00261-004-0233-0

Source DB:  PubMed          Journal:  Abdom Imaging        ISSN: 0942-8925


  6 in total

1.  Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging.

Authors:  Philip Aschoff; Christian Plathow; Thomas Beyer; Matthias P Lichy; Gunter Erb; Mehmet Ö Öksüz; Claus D Claussen; Christina Pfannenberg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-11-29       Impact factor: 9.236

2.  Effect of varying contrast material iodine concentration and injection technique on the conspicuity of hepatocellular carcinoma during 64-section MDCT of patients with cirrhosis.

Authors:  A Guerrisi; D Marin; R C Nelson; G De Filippis; M Di Martino; H Barnhart; R Masciangelo; I Guerrisi; R Passariello; C Catalano
Journal:  Br J Radiol       Date:  2011-08       Impact factor: 3.039

3.  A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney.

Authors:  Seung Chai Jung; Seung Hyup Kim; Jeong Yeon Cho
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

Review 4.  Hepatocellular Carcinoma: Current Imaging Modalities for Diagnosis and Prognosis.

Authors:  Maxime Ronot; Yvonne Purcell; Valérie Vilgrain
Journal:  Dig Dis Sci       Date:  2019-04       Impact factor: 3.199

5.  Imaging quality evaluation of low tube voltage coronary CT angiography using low concentration contrast medium.

Authors:  Chengzhong Zhang; Yuejun Yu; Zaixian Zhang; Qingguo Wang; Linfeng Zheng; Yan Feng; Zhiguo Zhou; Guixiang Zhang; Kangan Li
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

6.  Comparison of enhancement and image quality: different iodine concentrations for liver on 128-slice multidetector computed tomography in the same chronic liver disease patients.

Authors:  Byoung Goo Jo; Yun Gyu Song; Sang Goon Shim; Young Wook Kim
Journal:  Korean J Intern Med       Date:  2015-12-23       Impact factor: 2.884

  6 in total