Literature DB >> 15653089

Direct real-time measurement of in vivo forces in the lumbar spine.

Eric H Ledet1, Michael P Tymeson, Darryl J DiRisio, Benjamin Cohen, Richard L Uhl.   

Abstract

BACKGROUND CONTEXT: Accurate knowledge of the mechanical loads in the lumbar spine is critical to understanding the causes of degenerative disc disease and to developing suitable treatment options and functional disc replacements. To date, only indirect methods have been used to measure the forces developed in the spine in vivo. These methods are fraught with error, and results have never been validated using direct experimental measurements.
PURPOSE: The major aims of this study were to develop a methodology to directly measure, in real time, the in vivo loading in the lumbar spine, to determine if the forces developed in the lumbar spine are dependent on activity and/or posture and to assess the baboon as an animal model for human lumbar spine research based on in vivo mechanical loading. STUDY
DESIGN: Real-time telemetered data were collected from sensor-imbedded implants that were placed in the interbody space of the lumbar spines of two baboons.
METHODS: An interbody spinal implant was designed and instrumented with strain gauges to be used as a load cell. The implant was placed anteriorly in the lumbar spine of the baboon. Strain data were collected in vivo during normal activities and transmitted by means of a telemetry system to a receiver. The forces transmitted through the implant were calculated from the measured strain based on precalibration of the load cell. Measured forces were correlated to videotaped activities to elucidate trends in force level as a function of activity and posture over a 6-week period. The procedure was repeated in a second baboon, and data were recorded for similar activities.
RESULTS: Implants measured in vivo forces developed in the lumbar spine with less than 10% error. Loads in the lumbar spine are dependent on activity and posture. The maximum loads developed in the lumbar spine during normal (baboon) activities exceeded four times body weight and were recorded while animals were sitting flexed. Force data indicate similar trends between the human lumbar spine and the baboon lumbar spine.
CONCLUSIONS: It is possible to monitor the real-time forces present in the lumbar spine. Force data correlate well to trends previously reported for in vivo pressure data. Results also indicate that the baboon may be an appropriate animal model for study of the human lumbar spine.

Entities:  

Mesh:

Year:  2005        PMID: 15653089     DOI: 10.1016/j.spinee.2004.06.017

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  18 in total

1.  Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance.

Authors:  Christoph J Siepe; Karsten Wiechert; Mohamed F Khattab; Andreas Korge; H Michael Mayer
Journal:  Eur Spine J       Date:  2007-01-05       Impact factor: 3.134

Review 2.  Design concepts in lumbar total disc arthroplasty.

Authors:  Fabio Galbusera; Chiara M Bellini; Thomas Zweig; Stephen Ferguson; Manuela T Raimondi; Claudio Lamartina; Marco Brayda-Bruno; Maurizio Fornari
Journal:  Eur Spine J       Date:  2008-10-23       Impact factor: 3.134

Review 3.  Advances in the diagnosis of degenerated lumbar discs and their possible clinical application.

Authors:  Marco Brayda-Bruno; Marta Tibiletti; Keita Ito; Jeremy Fairbank; Fabio Galbusera; Alberto Zerbi; Sally Roberts; Ellen Wachtel; Yulia Merkher; Sarit Sara Sivan
Journal:  Eur Spine J       Date:  2013-08-27       Impact factor: 3.134

4.  Comparison of animal discs used in disc research to human lumbar disc: torsion mechanics and collagen content.

Authors:  Brent L Showalter; Jesse C Beckstein; John T Martin; Elizabeth E Beattie; Alejandro A Espinoza Orías; Thomas P Schaer; Edward J Vresilovic; Dawn M Elliott
Journal:  Spine (Phila Pa 1976)       Date:  2012-07-01       Impact factor: 3.468

5.  Comparison of lumbo-pelvic kinematics during trunk forward bending and backward return between patients with acute low back pain and asymptomatic controls.

Authors:  Iman Shojaei; Elizabeth G Salt; Quenten Hooker; Linda R Van Dillen; Babak Bazrgari
Journal:  Clin Biomech (Bristol, Avon)       Date:  2016-12-10       Impact factor: 2.063

6.  Heritability of lumbar trabecular bone mechanical properties in baboons.

Authors:  L M Havill; M R Allen; T L Bredbenner; D B Burr; D P Nicolella; C H Turner; D M Warren; M C Mahaney
Journal:  Bone       Date:  2009-11-10       Impact factor: 4.398

7.  Biomechanical and in vivo evaluation of experimental closure devices of the annulus fibrosus designed for a goat nucleus replacement model.

Authors:  Johannes L Bron; Albert J van der Veen; Marco N Helder; Barend J van Royen; Theodoor H Smit
Journal:  Eur Spine J       Date:  2010-04-17       Impact factor: 3.134

8.  Mature runt cow lumbar intradiscal pressures and motion segment biomechanics.

Authors:  Glenn Robin Buttermann; Brian P Beaubien; Louis C Saeger
Journal:  Spine J       Date:  2007-11-26       Impact factor: 4.166

9.  In vivo loads in the lumbar L3-4 disc during a weight lifting extension.

Authors:  Shaobai Wang; Won Man Park; Yoon Hyuk Kim; Thomas Cha; Kirkham Wood; Guoan Li
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-12-04       Impact factor: 2.063

10.  THREE-DIMENSIONAL MULTI-SEGMENTED SPINE JOINT REACTION FORCES DURING COMMON WORKPLACE PHYSICAL DEMANDS/ACTIVITIES OF DAILY LIVING.

Authors:  Scott P Breloff; Li-Shan Chou
Journal:  Biomed Eng (Singapore)       Date:  2017-08-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.