Literature DB >> 15653084

Restoring geometric and loading alignment of the thoracic spine with a vertebral compression fracture: effects of balloon (bone tamp) inflation and spinal extension.

Ioannis N Gaitanis1, Gerard Carandang, Frank M Phillips, Brian Magovern, Alexander J Ghanayem, Leonard I Voronov, Robert M Havey, Michael R Zindrick, Alexander G Hadjipavlou, Avinash G Patwardhan.   

Abstract

BACKGROUND CONTEXT: In patients with osteoporosis, changes in spinal alignment after a vertebral compression fracture (VCF) are believed to increase the risk of fracture of the adjacent vertebrae. The alterations in spinal biomechanics as a result of osteoporotic VCF and the effects of deformity correction on the loads in the adjacent vertebral bodies are not fully understood.
PURPOSE: To measure 1) the effect of thoracic VCFs on kyphosis (geometric alignment) and the shift of the physiologic compressive load path (loading alignment), 2) the effect of fracture reduction by balloon (bone tamp) inflation in restoring normal geometric and loading alignment and 3) the effect of spinal extension alone on fracture reduction and restoration of normal geometric and loading alignment. STUDY DESIGN/
SETTING: A biomechanical study using six fresh human thoracic specimens, each consisting of three adjacent vertebrae with all soft tissues and bony structures intact.
METHODS: In order to reliably create fracture, cancellous bone in the middle vertebral body was disrupted by inflation of bone tamps. After removal of the bone tamps, the specimen was compressed using bilateral loading cables until a fracture was observed with anterior vertebral body height loss of >/=25%. Fracture reduction was performed under a compressive preload of 250 N first under the application of extension moments, and then using inflatable bone tamps. The vertebral body heights, kyphotic deformity of the fractured vertebra and adjacent segments and location of compressive load (cable) path in the fractured and adjacent vertebral bodies were measured on video-fluoroscopic images.
RESULTS: The VCF caused anterior wall height loss of 37+/-15%, middle-height loss of 34+/-16%, segmental kyphosis increase of 14+/-7.0 degrees and vertebral kyphosis increase of 13+/-5.5 degrees (p<.05). The compressive load path shifted anteriorly by about 20% of anteroposterior end plate width in the fractured and adjacent vertebrae (p=.008). Bone tamp inflation restored the anterior wall height to 91+/-8.9%, middle-height to 91+/-14% and segmental kyphosis to within 5.6+/-5.9 degrees of prefracture values. The compressive load path returned posteriorly relative to the postfracture location in all three vertebrae (p=.004): the load path remained anterior to the prefracture location by about 9% to 11% of the anteroposterior end plate width. With application of extension moment (6.3+/-2.2 Nm) until segmental kyphosis and compressive load path were fully restored, anterior vertebral body heights were improved to 85+/-8.6% of prefracture values. However, the middle vertebral body height was not restored and vertebral kyphotic deformity remained significantly larger than the prefracture values (p<.05).
CONCLUSIONS: The anterior shift of the compressive load path in vertebral bodies adjacent to VCF can induce additional flexion moments on these vertebrae. This eccentric loading may contribute to the increased risk of new fractures in osteoporotic vertebrae adjacent to an uncorrected VCF deformity. Bone tamp inflation under a physiologic preload significantly reduced the VCF deformity (anterior and middle vertebral body heights, segmental and vertebral kyphosis) and returned the compressive load path posteriorly, approaching the prefracture alignment. Application of extension moments also was effective in restoring the prefracture geometric and loading alignment of adjacent segments, but the middle height of the fractured vertebra and vertebral kyphotic deformity were not restored with spinal extension alone.

Entities:  

Mesh:

Year:  2005        PMID: 15653084     DOI: 10.1016/j.spinee.2004.05.248

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  12 in total

1.  Internal fixation with percutaneous kyphoplasty compared with simple percutaneous kyphoplasty for thoracolumbar burst fractures in elderly patients: a prospective randomized controlled trial.

Authors:  Dengwei He; Lijun Wu; Xiaoyong Sheng; Qinqin Xiao; Ye Zhu; Weiyang Yu; Feijun Liu; Kejun Zhu
Journal:  Eur Spine J       Date:  2013-09-01       Impact factor: 3.134

2.  Pedicle screw fixation with kyphoplasty decreases the fracture risk of the treated and adjacent non-treated vertebral bodies: a finite element analysis.

Authors:  Pan Yang; Ying Zhang; Huan-Wen Ding; Jian Liu; Lin-Qiang Ye; Jin Xiao; Qiang Tu; Tao Yang; Fei Wang; Guo-Gang Sun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2016-12-07

3.  [Posttraumatic deformity of the thoracolumbar spine].

Authors:  Miguel Pishnamaz; Matti Scholz; Per D Trobisch; Philipp Lichte; Christian Herren; Frank Hildebrand; Philipp Kobbe
Journal:  Unfallchirurg       Date:  2020-02       Impact factor: 1.000

4.  Restoration of spinal alignment and disk mechanics following polyetheretherketone wafer kyphoplasty with StaXx FX.

Authors:  S M Renner; P P Tsitsopoulos; A T Dimitriadis; L I Voronov; R M Havey; G Carandang; B McIntosh; C Carson; D Ty; J G Ringelstein; A G Patwardhan
Journal:  AJNR Am J Neuroradiol       Date:  2011-06-16       Impact factor: 3.825

5.  Osteoporotic vertebral compression fractures and vertebral augmentation.

Authors:  Kimi L Kondo
Journal:  Semin Intervent Radiol       Date:  2008-12       Impact factor: 1.513

6.  The relationship between the spinopelvic balance and the incidence of adjacent vertebral fractures following percutaneous vertebroplasty.

Authors:  S-W Baek; C Kim; H Chang
Journal:  Osteoporos Int       Date:  2015-01-27       Impact factor: 4.507

7.  Incidence and risk factors for early adjacent vertebral fractures after balloon kyphoplasty for osteoporotic fractures: analysis of the SWISSspine registry.

Authors:  Christian Spross; Emin Aghayev; Rouven Kocher; Christoph Röder; Thomas Forster; Fabrice A Kuelling
Journal:  Eur Spine J       Date:  2013-10-02       Impact factor: 3.134

8.  Altered disc pressure profile after an osteoporotic vertebral fracture is a risk factor for adjacent vertebral body fracture.

Authors:  Michael N Tzermiadianos; Susan M Renner; Frank M Phillips; Alexander G Hadjipavlou; Michael R Zindrick; Robert M Havey; Michael Voronov; Avinash G Patwardhan
Journal:  Eur Spine J       Date:  2008-09-16       Impact factor: 3.134

9.  A computer-based measure of irregularity in vertebral alignment is a BMD-independent predictor of fracture risk in postmenopausal women.

Authors:  P C Pettersen; M de Bruijne; J Chen; Q He; C Christiansen; L B Tankó
Journal:  Osteoporos Int       Date:  2007-05-22       Impact factor: 4.507

10.  Percutaneous kyphoplasty with or without temporary unipedicle screw reduction : A retrospective comparative study of osteoporotic vertebral fractures.

Authors:  T Zhu; Y Tian; F Zhou; L Shang; Y Guo; Y Lv
Journal:  Orthopade       Date:  2016-07       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.