Literature DB >> 15642028

Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale.

Yongsik Kim1, Tae-Ju Oh, Carl E Misch, Hom-Lay Wang.   

Abstract

Due to lack of the periodontal ligament, osseointegrated implants, unlike natural teeth, react biomechanically in a different fashion to occlusal force. It is therefore believed that dental implants may be more prone to occlusal overloading, which is often regarded as one of the potential causes for peri-implant bone loss and failure of the implant/implant prosthesis. Overloading factors that may negatively influence on implant longevity include large cantilevers, parafunctions, improper occlusal designs, and premature contacts. Hence, it is important to control implant occlusion within physiologic limit and thus provide optimal implant load to ensure a long-term implant success. The purposes of this paper are to discuss the importance of implant occlusion for implant longevity and to provide clinical guidelines of optimal implant occlusion and possible solutions managing complications related to implant occlusion. It must be emphasized that currently there is no evidence-based, implant-specific concept of occlusion. Future studies in this area are needed to clarify the relationship between occlusion and implant success.

Entities:  

Mesh:

Year:  2005        PMID: 15642028     DOI: 10.1111/j.1600-0501.2004.01067.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  53 in total

1.  Case studies on local orthodontic traction by minis-implants before implant rehabilitation.

Authors:  Pei Shen; Wei-Feng Xu; Zhi-Gui Ma; Shan-Yong Zhang; Ying Zhang
Journal:  Int J Clin Exp Med       Date:  2015-05-15

2.  Managing prosthetic complication in implant-retained overdenture.

Authors:  Navneet Dhillon; S K Roy Chowdhury; Prashant Kumar; Rahul Menon
Journal:  Med J Armed Forces India       Date:  2013-02-23

3.  Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

Authors:  W Aunmeungtong; P Khongkhunthian; P Rungsiyakull
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

4.  [Quantitative analysis of occlusal changes in posterior partial fixed implant supported prostheses].

Authors:  Q Luo; Q Ding; L Zhang; Q F Xie
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-12-18

5.  [Interarch distance is a target restorative space value: clinical decisionmaking of implant restoration guided by measured value].

Authors:  Yu-Qiang Zhang; Hai-Yang Yu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2021-04-01

6.  Nasal floor augmentation for the reconstruction of the atrophic maxilla: a case series.

Authors:  Moustafa El-Ghareeb; Joan Pi-Anfruns; Mohammed Khosousi; Tara Aghaloo; Peter Moy
Journal:  J Oral Maxillofac Surg       Date:  2011-12-16       Impact factor: 1.895

7.  Finite Element Analysis of effect of cusp inclination and occlusal contacts in PFM and PEEK implant-supported crowns on resultant stresses.

Authors:  Githanjali Manchikalapudi; Sreeramulu Basapogu
Journal:  Med J Armed Forces India       Date:  2021-01-16

8.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

9.  Peri-implantitis and the prosthodontist.

Authors:  A Dawood; B Marti Marti; S Tanner
Journal:  Br Dent J       Date:  2017-09-08       Impact factor: 1.626

10.  In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns.

Authors:  Martin Rosentritt; Sebastian Hahnel; Frank Engelhardt; Michael Behr; Verena Preis
Journal:  Clin Oral Investig       Date:  2016-07-01       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.