M Kamínek1, M Myslivecek, M Skvarilová, V Husák, O Lang.
Abstract
The authors compared retrospectively the diagnostic accuracy of three protocols--201Tl stress-redistribution, 2-day 99mTc-tetrofosmin and the dual-isotope protocol (rest 201Tl/stress99m Tc-tetrofosmin)--for the detection of ischaemic heart disease (IHD) in a total of 115 patients without previous myocardial infarction (IM). 201Tl protocol (group A) was used to examine 43 patients, incl. 15 women, mean age 51 years (38-69 years). The 2-day 99m Tc-tetrofosmin protocol was used to examine 39 patients incl. 12 women, mean age 49 years (30-71 years). The dual-isotope protocol was used in 33 patients, incl. 8 women, mean age 52 years (31-69 years). In all patients coronarography was performed, stenosis of the artery >50% was considered significant for IHD. The sensitivity of the dual-isotope protocol was 95% and 96% resp. and 92% in the 2-day tetrofosmin and 201Tl protocol, (p>0.05). The specificity of the dual-isotope protocol was 82% and 89% resp. and 88% in the 201Tl and 2-day tetrofosmin protocol, (p >0.05). The diagnostic accuracy was 91% in the dualisotope and 201Tl protocol and 92% in the 2-day protocol (p>0.05). No significant difference was revealed in the sensitivity, specificity and diagnostic accuracy for the detection of IHD between different protocols in patients without previous IM.Entities:
Mesh:
Substances:
Year: 1999 PMID: 15641225
Source DB: PubMed Journal: Vnitr Lek ISSN: 0042-773X