Literature DB >> 15641138

A non-invasive method for gastrointestinal parameter monitoring.

Wen-Xing Wang1, Guo-Zheng Yan, Fang Sun, Ping-Ping Jiang, Wen-Qiang Zhang, Gen-Fu Zhang.   

Abstract

AIM: To propose a new, non-invasive method for monitoring 24-h pressure, temperature and pH value in gastrointestinal tract.
METHODS: The authors developed a miniature, multi-functional gastrointestinal monitoring system, which comprises a set of indigestible biotelemetry capsules and a data recorder. The capsule, after ingested by patients, could measure pressure, temperature and pH value in the gastrointestinal tract and transmit the data to the data recorder outside the body through a 434 MHz radio frequency data link. After the capsule passed out from the body, the data saved in the recorder were downloaded to a workstation via a special software for further analysis and comparison.
RESULTS: Clinical experiments showed that the biotelemetry capsules could be swallowed by volunteers without any difficulties. The data recorder could receive the radio frequency signals transmitted by the biotelemetry in the body. The biotelemetry capsule could pass out from the body without difficulties. No discomfort was reported by any volunteer during the experiment. In vivo pressure and temperature data were acquired.
CONCLUSION: A non-invasive method for monitoring 24-h gastrointestinal parameters was proposed and tested by the authors. The feasibility and functionality of this method are verified by laboratory tests and clinical experiments.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15641138      PMCID: PMC4250803          DOI: 10.3748/wjg.v11.i4.521

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  28 in total

1.  The role of 24-hr gastric pH-monitoring in the interpretation of 24-hr gastric bile monitoring for duodenogastric reflux.

Authors:  K H Fuchs; M Fein; J Maroske; J Heimbucher; S M Freys
Journal:  Hepatogastroenterology       Date:  1999 Jan-Feb

2.  A novel method for real-time magnetic marker monitoring in the gastrointestinal tract.

Authors:  W Andrä; H Danan; W Kirmsse; H H Kramer; P Saupe; R Schmieg; M E Bellemann
Journal:  Phys Med Biol       Date:  2000-10       Impact factor: 3.609

3.  Magnetic marker monitoring of disintegrating capsules.

Authors:  W Weitschies; M Karaus; D Cordini; L Trahms; J Breitkreutz; W Semmler
Journal:  Eur J Pharm Sci       Date:  2001-07       Impact factor: 4.384

4.  Small bowel motility: relationship between smooth muscle contraction and electroenterogram signal.

Authors:  J L Martinez-de-Juan; J Saiz; M Meseguer; J L Ponce
Journal:  Med Eng Phys       Date:  2000-04       Impact factor: 2.242

5.  Motility in the isolated mouse colon: migrating motor complexes, myoelectric complexes and pressure waves.

Authors:  A K Powell; R Fida; R A R Bywater
Journal:  Neurogastroenterol Motil       Date:  2003-06       Impact factor: 3.598

6.  Bowel sounds analysis: a novel noninvasive method for diagnosis of small-volume ascites.

Authors:  Christos Liatsos; Leontios J Hadjileontiadis; Christos Mavrogiannis; David Patch; Stavros M Panas; Andrew K Burroughs
Journal:  Dig Dis Sci       Date:  2003-08       Impact factor: 3.199

7.  RF performance of a 418-MHz radio telemeter packaged for human vaginal placement.

Authors:  W G Scanlon; N E Evans; Z M McCreesh
Journal:  IEEE Trans Biomed Eng       Date:  1997-05       Impact factor: 4.538

8.  [Ultrasound detection of gastric antrum motility--evaluating a simple semiquantitative method].

Authors:  B Wedmann; R J Adamek; M Wegener
Journal:  Ultraschall Med       Date:  1995-06       Impact factor: 6.548

Review 9.  Intraluminal pH of the human gastrointestinal tract.

Authors:  J Fallingborg
Journal:  Dan Med Bull       Date:  1999-06

Review 10.  Disorders of gastrointestinal motility in neurologic diseases.

Authors:  M Camilleri
Journal:  Mayo Clin Proc       Date:  1990-06       Impact factor: 7.616

View more
  2 in total

1.  Non-invasive measurement of pan-colonic pressure over a whole digestive cycle: clinical applications of a capsule-style manometric system.

Authors:  Wen-Qiang Zhang; Guo-Zheng Yan; Lian-Zhi Yu; Xin-Qing Yang
Journal:  World J Gastroenterol       Date:  2006-12-21       Impact factor: 5.742

2.  Low-power wireless electronic capsule for long-term gastrointestinal monitoring.

Authors:  Kai Zhao; Guozheng Yan; Li Lu; Fei Xu
Journal:  J Med Syst       Date:  2015-01-29       Impact factor: 4.460

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.