Literature DB >> 11049189

A novel method for real-time magnetic marker monitoring in the gastrointestinal tract.

W Andrä1, H Danan, W Kirmsse, H H Kramer, P Saupe, R Schmieg, M E Bellemann.   

Abstract

In internal medicine, a simple method for the functional examination of the gastrointestinal tract without the risk of radiation exposure is required. We describe a novel principle based on the monitoring of magnetic markers which meets these demands. Our method employs a special permanent magnet which is repeatedly aligned by a vertically oriented pulsed magnetic field. Due to this alignment, the marker position can be derived from the stray field components measured by commercial field sensors. Our method was evaluated by means of a 3D intestinal phantom. The monitoring procedure yielded the time course of the marker position as a 3D plot either in real-time or as a time-lapse movie. The spatial resolution, expressed by the mean square deviation, was better than 10 mm and is thus sufficiently high to distinguish between adjacent loops of the gut. The temporal resolution, i.e. the minimum time between two successive measurements, was about 1 s. The presented method has very moderate technical demands and allows us to monitor magnetic markers in real-time. The technique may be useful with respect to functional examination of the gastrointestinal tract. In pharmaceutical research, our method offers the opportunity for remote drug release at any position of the gut.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11049189     DOI: 10.1088/0031-9155/45/10/322

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

Review 1.  Biomagnetic methods: technologies applied to pharmaceutical research.

Authors:  Luciana A Corá; Madileine F Américo; Ricardo B Oliveira; Cristina H R Serra; Oswaldo Baffa; Raul C Evangelista; Giselle F Oliveira; José Ricardo Aruda Miranda
Journal:  Pharm Res       Date:  2010-10-15       Impact factor: 4.200

2.  Understanding gastric forces calculated from high-resolution pill tracking.

Authors:  Bryan Laulicht; Anubhav Tripathi; Vincent Schlageter; Pavel Kucera; Edith Mathiowitz
Journal:  Proc Natl Acad Sci U S A       Date:  2010-04-19       Impact factor: 11.205

3.  A non-invasive method for gastrointestinal parameter monitoring.

Authors:  Wen-Xing Wang; Guo-Zheng Yan; Fang Sun; Ping-Ping Jiang; Wen-Qiang Zhang; Gen-Fu Zhang
Journal:  World J Gastroenterol       Date:  2005-01-28       Impact factor: 5.742

4.  Towards a magnetic localization system for 3-D tracking of tongue movements in speech-language therapy.

Authors:  Chihwen Cheng; Xueliang Huo; Maysam Ghovanloo
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

5.  Gastric transit and small intestinal transit time and motility assessed by a magnet tracking system.

Authors:  Jonas Worsøe; Lotte Fynne; Tine Gregersen; Vincent Schlageter; Lisbet A Christensen; Jens F Dahlerup; Nico J M Rijkhoff; Søren Laurberg; Klaus Krogh
Journal:  BMC Gastroenterol       Date:  2011-12-29       Impact factor: 3.067

6.  Localization accuracy of multiple magnets in a myokinetic control interface.

Authors:  Marta Gherardini; Francesco Clemente; Stefano Milici; Christian Cipriani
Journal:  Sci Rep       Date:  2021-03-01       Impact factor: 4.996

7.  Application of In Vivo MRI Imaging to Track a Coated Capsule and Its Disintegration in the Gastrointestinal Tract in Human Volunteers.

Authors:  Sarah Sulaiman; Pavel Gershkovich; Caroline L Hoad; Matthew Calladine; Robin C Spiller; Snow Stolnik; Luca Marciani
Journal:  Pharmaceutics       Date:  2022-01-24       Impact factor: 6.321

8.  The myokinetic control interface: tracking implanted magnets as a means for prosthetic control.

Authors:  S Tarantino; F Clemente; D Barone; M Controzzi; C Cipriani
Journal:  Sci Rep       Date:  2017-12-07       Impact factor: 4.379

9.  Acoustic Sensing and Ultrasonic Drug Delivery in Multimodal Theranostic Capsule Endoscopy.

Authors:  Fraser R Stewart; Yongqiang Qiu; Holly S Lay; Ian P Newton; Benjamin F Cox; Mohammed A Al-Rawhani; James Beeley; Yangminghao Liu; Zhihong Huang; David R S Cumming; Inke Näthke; Sandy Cochran
Journal:  Sensors (Basel)       Date:  2017-07-03       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.