Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations.

Edward J Soares1, Stephen J Glick, John W Hoppin.   

Abstract

In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases of RBI-EM, maximum-likelihood EM (ML-EM) and ordered-subset EM (OS-EM), and the special case of RBI-SMART, SMART. Explicit expressions were found for the ensemble mean, covariance matrix, and probability density function of RBI reconstructed images, as a function of iteration number. The theoretical formulations relied on one approximation, namely that the noise in the reconstructed image was small compared to the mean image. In this paper, we evaluate the predictions of the theory by using Monte Carlo methods to calculate the sample statistical properties of each algorithm and then compare the results with the theoretical formulations. In addition, the validity of the approximation will be justified.

Entities:  

Mesh:

Year:  2005        PMID: 15638190     DOI: 10.1109/tmi.2004.836876

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease.

Authors:  Bailing Hsu; Fu-Chung Chen; Tao-Cheng Wu; Wen-Sheng Huang; Po-Nien Hou; Chien-Cheng Chen; Guang-Uei Hung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-08-21       Impact factor: 9.236

2.  Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation.

Authors:  S Tong; A M Alessio; P E Kinahan
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

3.  An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability.

Authors:  Xin He; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

4.  Estimation of noise properties for TV-regularized image reconstruction in computed tomography.

Authors:  Adrian A Sánchez
Journal:  Phys Med Biol       Date:  2015-08-26       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.