Literature DB >> 15626616

Magnetic Dynabeads detection by sensitive element based on giant magnetoimpedance.

Galina Kurlyandskaya1, Vladimir Levit.   

Abstract

A GMI-biosensor prototype was designed and fabricated using an amorphous ribbon. As a first step, a GMI response was measured with a model liquid media: suspension containing magnetisable Dynabeads M-450. These beads can be used as biomolecular labels when coated with a specific antibody. The GMI change caused by their presence was measured with a biosensor prototype designed with a measuring cell containing an amorphous CoFeMoSiB-ribbon element. GMI was measured at a range of current frequencies from 0.3 to 10 MHz and at intensities of either Irms=3 or 4.5 mA. Commercial Dynabeads M-450 were supplied as a suspension in a phosphate buffered saline. A maximum difference of 25% in the GMI ratio measured with and without Dynabeads was obtained at a frequency of 3.5 MHz and Irms=3 mA. Some potential applications for GMI-biosensor and further directions are proposed.

Entities:  

Mesh:

Year:  2005        PMID: 15626616     DOI: 10.1016/j.bios.2004.04.027

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

Review 1.  Magnetic biosensor technologies for medical applications: a review.

Authors:  J Llandro; J J Palfreyman; A Ionescu; C H W Barnes
Journal:  Med Biol Eng Comput       Date:  2010-06-24       Impact factor: 2.602

Review 2.  Design and synthesis of magnetic nanoparticles for biomedical diagnostics.

Authors:  Yuan Chen; Xianguang Ding; Yan Zhang; Auginia Natalia; Xuecheng Sun; Zhigang Wang; Huilin Shao
Journal:  Quant Imaging Med Surg       Date:  2018-10

3.  Transverse susceptibility as a biosensor for detection of Au-Fe₃O₄ nanoparticle-embedded human embryonic kidney cells.

Authors:  Natalie Frey Huls; Manh-Huong Phan; Arun Kumar; Subhra Mohapatra; Shyam Mohapatra; Pritish Mukherjee; Hariharan Srikanth
Journal:  Sensors (Basel)       Date:  2013-07-03       Impact factor: 3.576

4.  A magnetic nanobead-based bioassay provides sensitive detection of single- and biplex bacterial DNA using a portable AC susceptometer.

Authors:  Mattias Strömberg; Teresa Zardán Gómez de la Torre; Mats Nilsson; Peter Svedlindh; Maria Strømme
Journal:  Biotechnol J       Date:  2013-12-19       Impact factor: 4.677

Review 5.  Magnetoimpedance Biosensors and Real-Time Healthcare Monitors: Progress, Opportunities, and Challenges.

Authors:  Valery Ortiz Jimenez; Kee Young Hwang; Dang Nguyen; Yasif Rahman; Claire Albrecht; Baylee Senator; Ongard Thiabgoh; Jagannath Devkota; Vinh Duc An Bui; Dao Son Lam; Tatiana Eggers; Manh-Huong Phan
Journal:  Biosensors (Basel)       Date:  2022-07-12

6.  Study on Detection of a Small Magnetic Particle Using Thin Film Magneto-Impedance Sensor with Subjecting to Strong Normal Field.

Authors:  Tomoo Nakai
Journal:  Micromachines (Basel)       Date:  2022-07-28       Impact factor: 3.523

Review 7.  Magneto-Impedance Biosensor Sensitivity: Effect and Enhancement.

Authors:  Abkar Sayad; Efstratios Skafidas; Patrick Kwan
Journal:  Sensors (Basel)       Date:  2020-09-12       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.