Literature DB >> 15616741

Perfusion and chemical monitoring of living cells on a microfluidic chip.

Jonathan G Shackman1, Gabriella M Dahlgren, Jennifer L Peters, Robert T Kennedy.   

Abstract

A microfluidic device that incorporates continuous perfusion and an on-line electrophoresis immunoassay was developed, characterized, and applied to monitoring insulin secretion from single islets of Langerhans. In the device, a cell chamber was perfused with cell culture media or a balanced salt solution at 0.6 to 1.5 microL min(-1). The flow was driven by gas pressure applied off-chip. Perfusate was continuously sampled at 2 nL min(-1) by electroosmosis through a separate channel on the chip. The perfusate was mixed on-line with fluorescein isothiocyanate-labeled insulin (FITC-insulin) and monoclonal anti-insulin antibody and allowed to react for 60 s as the mixture traveled down a 4 cm long reaction channel. The cell chamber and reaction channel were maintained at 37 degrees C. The reaction mixture was injected onto a 1.5 cm separation channel as rapidly as every 6 s, and the free FITC-insulin and the FITC-insulin-antibody complex were separated under an electric field of 500 to 600 V cm(-1). The immunoassay had a detection limit of 0.8 nM and a relative standard deviation of 6% during 2 h of continuous operation with standard solutions. Individual islets were monitored for up to 1 h while perfusing with different concentrations of glucose. The immunoassay allowed quantitative monitoring of classical biphasic and oscillatory insulin secretion with 6 s sampling frequency following step changes in glucose from 3 to 11 mM. The 2.5 cm x 7.6 cm microfluidic system allowed for monitoring islets in a highly automated fashion. The technique should be amenable to studies involving other tissues or cells that release chemicals.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15616741     DOI: 10.1039/b404974h

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  36 in total

1.  Biosensors for immune cell analysis-A perspective.

Authors:  Alexander Revzin; Emanual Maverakis; H-C Chang
Journal:  Biomicrofluidics       Date:  2012-04-26       Impact factor: 2.800

2.  Towards monitoring real-time cellular response using an integrated microfluidics-matrix assisted laser desorption ionisation/nanoelectrospray ionisation-ion mobility-mass spectrometry platform.

Authors:  J R Enders; C C Marasco; A Kole; B Nguyen; S Sevugarajan; K T Seale; J P Wikswo; J A McLean
Journal:  IET Syst Biol       Date:  2010-11       Impact factor: 1.615

3.  Dynamic monitoring of glucagon secretion from living cells on a microfluidic chip.

Authors:  Jonathan G Shackman; Kendra R Reid; Colleen E Dugan; Robert T Kennedy
Journal:  Anal Bioanal Chem       Date:  2012-03       Impact factor: 4.142

4.  A multiwalled carbon nanotube/dihydropyran composite film electrode for insulin detection in a microphysiometer chamber.

Authors:  Rachel M Snider; Madalina Ciobanu; Amy E Rue; David E Cliffel
Journal:  Anal Chim Acta       Date:  2008-01-06       Impact factor: 6.558

5.  Quantitative measurement of zinc secretion from pancreatic islets with high temporal resolution using droplet-based microfluidics.

Authors:  Christopher J Easley; Jonathan V Rocheleau; W Steven Head; David W Piston
Journal:  Anal Chem       Date:  2009-11-01       Impact factor: 6.986

6.  Synchronized stimulation and continuous insulin sensing in a microfluidic human Islet on a Chip designed for scalable manufacturing.

Authors:  Aaron L Glieberman; Benjamin D Pope; John F Zimmerman; Qihan Liu; John P Ferrier; Jennifer H R Kenty; Adrian M Schrell; Nikita Mukhitov; Kevin L Shores; Adrian Buganza Tepole; Douglas A Melton; Michael G Roper; Kevin Kit Parker
Journal:  Lab Chip       Date:  2019-09-10       Impact factor: 6.799

7.  Microfluidic perfusion system for automated delivery of temporal gradients to islets of Langerhans.

Authors:  Xinyu Zhang; Michael G Roper
Journal:  Anal Chem       Date:  2009-02-01       Impact factor: 6.986

8.  In Vitro Platform for Studying Human Insulin Release Dynamics of Single Pancreatic Islet Microtissues at High Resolution.

Authors:  Patrick M Misun; Burçak Yesildag; Felix Forschler; Aparna Neelakandhan; Nassim Rousset; Adelinn Biernath; Andreas Hierlemann; Olivier Frey
Journal:  Adv Biosyst       Date:  2020-01-29

9.  Continuous-flow enzyme assay on a microfluidic chip for monitoring glycerol secretion from cultured adipocytes.

Authors:  Anna M Clark; Kyle M Sousa; Colin Jennings; Ormond A MacDougald; Robert T Kennedy
Journal:  Anal Chem       Date:  2009-03-15       Impact factor: 6.986

Review 10.  A mathematical method for extracting cell secretion rate from affinity biosensors continuously monitoring cell activity.

Authors:  Yandong Gao; Qing Zhou; Zimple Matharu; Ying Liu; Timothy Kwa; Alexander Revzin
Journal:  Biomicrofluidics       Date:  2014-04-30       Impact factor: 2.800

View more