Literature DB >> 15616119

Contrast-enhanced MR Angiography of the renal arteries: blinded multicenter crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine.

Mathias Prokop1, Günther Schneider, Angelo Vanzulli, Mathias Goyen, Stefan G Ruehm, Philippe Douek, Massimo Daprà, Gianpaolo Pirovano, Miles A Kirchin, Alberto Spinazzi.   

Abstract

PURPOSE: To prospectively and intraindividually compare 0.1 mmol/kg gadobenate dimeglumine with 0.2 mmol/kg gadopentetate dimeglumine for contrast material-enhanced magnetic resonance (MR) angiography of the renal arteries.
MATERIALS AND METHODS: Institutional review board approval was granted by each of three participating centers. The study accorded with international standards for good clinical practice and Declaration of Helsinki and subsequent amendments. Patients gave written informed consent before enrollment. Patients (n = 34) underwent two MR angiographic examinations more than 48 hours but less than 12 days apart. Gadobenate dimeglumine followed by gadopentetate dimeglumine was administered in 18 patients; the order of administration was reversed in 16 patients. A 1.5-T MR imager was used with a phase-encoded three-dimensional spoiled breath-hold pulse sequence. Two blinded independent readers qualitatively assessed randomized subtracted maximum intensity projection images. A three-point scale for diagnostic quality (0, poor; 1a or 1p, moderate; and 2a or 2p, adequate [a and p refer, respectively, to absence and presence of vascular lesions]) was used to score each of nine segments of the abdominal aorta and both renal arteries (possible overall score, 18). Quantitative assessment (vessel signal-to-noise ratio [SNR], vessel-muscle contrast-to-noise ratio [CNR]) of source images was performed for regions of interest in supra-, juxta-, and infrarenal aorta segments and psoas muscle. Data were tested with analysis of variance for two-period crossover design. Interreader agreement was evaluated with Cohen kappa statistics.
RESULTS: No difference in mean image quality between the two contrast agents was observed; scores for gadobenate dimeglumine and gadopentetate dimeglumine were 15.15 and 15.23 for reader 1 and 16.77 and 17.01 for reader 2. The order of contrast material administration likewise produced no quality differences: readers 1 and 2 reported scores of 14.4 +/- 4.2 (standard deviation) and 16.7 +/- 2.3, respectively, when gadobenate dimeglumine was given first, and 15.2 +/- 1.8 and 16.6 +/- 1.6, respectively, when gadopentetate dimeglumine was given first. Results of quantitative evaluation showed increasing SNR and CNR with gadobenate dimeglumine in segments at progressively lower levels of the aorta, but increases in SNR and CNR at the infrarenal aorta (48.3 vs 40.6 and 44.2 vs 36.4, respectively) were not significant (P = .05 for both).
CONCLUSION: Gadobenate dimeglumine at a dose of 0.1 mmol/kg is comparable to gadopentetate dimeglumine at 0.2 mmol/kg for contrast-enhanced renal MR angiography. (c) RSNA, 2004.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15616119     DOI: 10.1148/radiol.2342040023

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

Review 1.  Gadolinium contrast agents for CNS imaging: current concepts and clinical evidence.

Authors:  E Kanal; K Maravilla; H A Rowley
Journal:  AJNR Am J Neuroradiol       Date:  2014-05-22       Impact factor: 3.825

Review 2.  Macromolecules, dendrimers, and nanomaterials in magnetic resonance imaging: the interplay between size, function, and pharmacokinetics.

Authors:  Aaron Joseph L Villaraza; Ambika Bumb; Martin W Brechbiel
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

3.  Contrast-enhanced MR angiography: does a higher relaxivity MR contrast agent permit a reduction of the dose administered for routine vascular imaging applications?

Authors:  Xiaoying Xing; Xiangzhu Zeng; Xuan Li; Qiang Zhao; Miles A Kirchin; Gianpaolo Pirovano; Xiaoying Wang; Yuan Li; Roberto Iezzi; Francesco De Cobelli
Journal:  Radiol Med       Date:  2014-09-03       Impact factor: 3.469

4.  Signal quality of single dose gadobenate dimeglumine pulmonary MRA examinations exceeds quality of MRA performed with double dose gadopentetate dimeglumine.

Authors:  Pamela K Woodard; Thomas L Chenevert; H Dirk Sostman; Kathleen A Jablonski; Paul D Stein; Lawrence R Goodman; Frank J Londy; Vamsidhar Narra; Charles A Hales; Russell D Hull; Victor F Tapson; John G Weg
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-20       Impact factor: 2.357

5.  Comparison of gadobenate dimeglumine and gadodiamide in the evaluation of spinal vascular anatomy with MR angiography.

Authors:  M V Spampinato; S A Nguyen; Z Rumboldt
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-06       Impact factor: 3.825

6.  Multicenter, intraindividual comparison of single-dose gadobenate dimeglumine and double-dose gadopentetate dimeglumine for MR angiography of the supra-aortic arteries (the Supra-Aortic VALUE study).

Authors:  Yanjun Li; X Li; D Li; J Lu; X Xing; F Yan; Yuan Li; X Wang; R Iezzi; F De Cobelli
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-04       Impact factor: 3.825

7.  Left ventricular infarct size assessed with 0.1 mmol/kg of gadobenate dimeglumine correlates with that assessed with 0.2 mmol/kg of gadopentetate dimeglumine.

Authors:  Monravee Tumkosit; Chirapa Puntawangkoon; Tim M Morgan; Hollins P Clark; Craig A Hamilton; William O Ntim; Paige B Clark; W Gregory Hundley
Journal:  J Comput Assist Tomogr       Date:  2009 May-Jun       Impact factor: 1.826

8.  Safety and adverse effects during 24 hours after contrast-enhanced MRI with gadobenate dimeglumine (MultiHance) in children.

Authors:  Guenther Schneider; Hellmut Schürholz; Miles A Kirchin; Arno Bücker; Peter Fries
Journal:  Pediatr Radiol       Date:  2012-11-24

9.  Follow-up of coiled cerebral aneurysms at 3T: comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography.

Authors:  N Anzalone; F Scomazzoni; M Cirillo; C Righi; F Simionato; M Cadioli; A Iadanza; M A Kirchin; G Scotti
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-12       Impact factor: 3.825

10.  Self-tracking of contrast kinetics for automatic triggering of contrast-enhanced whole-heart coronary magnetic resonance angiography.

Authors:  Himanshu Bhat; Peng Lai; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2009-04       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.